2020
DOI: 10.1016/j.jim.2020.112835
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of ELISAs for the quantitation of interleukin (IL)-1β, IL-6, IL-8 and IL-10 in ovine plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 27 publications
1
7
0
Order By: Relevance
“…According to the SPR response in Figure 8, the recoveries of DENV-2 E-proteins was calculated and tabulated in Table 3. The obtained average recovery was consistent with acceptable recovery, which is in the range of 80-120%, indicates that the proposed sensor can be used for detection and quantification of DENV-2 Eproteins in real samples [92][93][94][95]. Figure 7b depicts the selective shift of SPR angle of DENV-2 E-proteins in multiple analytes solution.…”
Section: Spr Performancessupporting
confidence: 66%
“…According to the SPR response in Figure 8, the recoveries of DENV-2 E-proteins was calculated and tabulated in Table 3. The obtained average recovery was consistent with acceptable recovery, which is in the range of 80-120%, indicates that the proposed sensor can be used for detection and quantification of DENV-2 Eproteins in real samples [92][93][94][95]. Figure 7b depicts the selective shift of SPR angle of DENV-2 E-proteins in multiple analytes solution.…”
Section: Spr Performancessupporting
confidence: 66%
“…An equation of the standard curve was constructed by regression analysis of the mean OD readings and the log of standard concentrations using the four-parameter logistic model (GraphPad Prism 8, GraphPad Software, San Diego, CA). Additionally, linear regression was fitted to the data points and a Student's t test was performed to compare slopes, thereby assessing parallelism between plasma and recombinant GH ( Bouquet et al, 2020 ). The GH concentration in each sample was calculated using this fitted equation based on the mean OD reading of each sample and presented as means ± SEM.…”
Section: Methodsmentioning
confidence: 99%
“…The concentration of interleukin‐6 (IL‐6), IL‐8, IL‐1β, and IL‐10 was measured in blood and in bronchoalveolar lavage (BAL) fluid. Our development of ovine‐specific ELISA assays has been described before (Bouquet et al, 2020 ). Detailed methods are provided in an online supplement.…”
Section: Methodsmentioning
confidence: 99%