2019
DOI: 10.1016/j.chroma.2019.06.034
|View full text |Cite|
|
Sign up to set email alerts
|

Development and validation of an ultra high performance liquid chromatography-tandem mass spectrometry method for the determination of phthalate esters in Greek grape marc spirits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(19 citation statements)
references
References 28 publications
2
17
0
Order By: Relevance
“…In addition, Perestrelo et al [ 60 ] used the SPME extraction procedure to analyze food-contacted plastics in which the amounts detected ranged from 1.0 to 2.8 µg/L for BBP and DOP, respectively. Diamantidou and collaborators [ 84 ] determined the levels of PAEs in 45 samples from Greek grape marc spirits using the ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The amounts in samples ranged from 1.25 to 113,220 µg/L for dipentyl phthalate (DPeP) and DEHP, respectively.…”
Section: Occurrence Of Phthalatesmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, Perestrelo et al [ 60 ] used the SPME extraction procedure to analyze food-contacted plastics in which the amounts detected ranged from 1.0 to 2.8 µg/L for BBP and DOP, respectively. Diamantidou and collaborators [ 84 ] determined the levels of PAEs in 45 samples from Greek grape marc spirits using the ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The amounts in samples ranged from 1.25 to 113,220 µg/L for dipentyl phthalate (DPeP) and DEHP, respectively.…”
Section: Occurrence Of Phthalatesmentioning
confidence: 99%
“…Recently, ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) compared to LC-MS/MS have the potentiality to separate the PAEs in a shorter run time (14 to 16 min) and use smaller particle LC columns (2.1 µm), which allows obtaining narrower peaks and high sample throughput [ 73 , 84 , 101 , 108 ]. Electrospray ionization (ESI) interface, triple quadrupole (QqQ), and/or quadrupole time of flight (TOF) mass analyzer and MRM modes are the most common combination used in LC-MS for quantification of PAEs [ 73 , 84 , 101 , 108 ]. Diamantidou et al [ 84 ] have proposed a direct UPLC-MS/MS for analysis of 12 PAEs in grape marc spirits of Greek origin.…”
Section: Analytical Approachesmentioning
confidence: 99%
See 1 more Smart Citation
“…Regulated substances and non-intentionally added substances (NIAS) migrating into food or official food simulants have been studied by different analytical approaches covering BPA, phthalates [150] and other NIAS [151].…”
Section: Assessment Of Food Safetymentioning
confidence: 99%
“…From our previous work, we found that chromatography techniques are the preferred methods of determining PAEs due to their accurate and stable results [1]. However, if these methods are employed to determine PAE contamination, GC/HPLC with UV/MS exhibits some disadvantages: tedious procedures, requiring large amounts of hazardous organic solvents, expensive to perform in a special laboratory, and necessitating professional operators [17]. Additionally, these instruments cannot be easily transported and run on site.…”
Section: Introductionmentioning
confidence: 99%