Development and validation of an UHPLC–MS/MS approach for simultaneous quantification of five bioactive saponins in rat plasma: Application to a comparative pharmacokinetic study of aqueous extracts of raw and salt-processed Achyranthes bidentata

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 14 publications
1
6
0
Order By: Relevance
“…The values of T max of the five saponins were within 1.0 h after oral administration. A double‐peak phenomenon of the five saponins is presented which was in agreement with our previous pharmacokinetic study (Tao, Du, Li, & Cai, ). The double‐peak phenomenon of chikusetsusaponin IV, chikusetsusaponin IVa and ginsenoside Ro was reported in the literature (Qi et al, ; Wang, Liu, Guo, & Wang, ; Zheng et al, ), and is probably due to distribution, reabsorption and enterohepatic circulation.…”
Section: Resultssupporting
confidence: 91%
“…The values of T max of the five saponins were within 1.0 h after oral administration. A double‐peak phenomenon of the five saponins is presented which was in agreement with our previous pharmacokinetic study (Tao, Du, Li, & Cai, ). The double‐peak phenomenon of chikusetsusaponin IV, chikusetsusaponin IVa and ginsenoside Ro was reported in the literature (Qi et al, ; Wang, Liu, Guo, & Wang, ; Zheng et al, ), and is probably due to distribution, reabsorption and enterohepatic circulation.…”
Section: Resultssupporting
confidence: 91%
“…A Thermo Scientific Dionex Ultimate 3000 UHPLC system with a Thermo High-Resolution Q Exactive Focus mass spectrometer (Thermo, Germany) were used for analysis, and the analytical method was derived from previous studies. , The injection volume was 1.0 μL. The chromatographic column was presented on a 100 mm × 2.1 mm Hypersil Gold instrument (Thermo Fisher Scientific) with a particle size of 1.9 μm.…”
Section: Methodsmentioning
confidence: 99%
“…TIC chromatograms of the individual standard compounds were shown in Figure 1. The eight components were unambiguously assigned as β-ecdysterone, 25S-inokosterone [15], achyranthoside D [16], ginsenoside Ro [15], chikusetsusaponin IV [17], achyranthoside C [16], chikusetsaponin IVa [17] and 13-HODE [8].…”
Section: Optimization Of Chromatographic and Mass Spectrometric Condimentioning