2004
DOI: 10.1016/j.powtec.2004.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a material-labeling method for powder process characterization using X-ray computed tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(14 citation statements)
references
References 28 publications
0
13
0
Order By: Relevance
“…In neither case was the resolution of the method clearly stated, but in the case of Ohgaki et al [23], spatial resolution appears to be on the order of some micrometers, albeit with significant noise in the strain data. Similar methods, but based on an addition of artificial markers, have also been used to study powder compaction and mixing, where a small number of lead-acetate impregnated cellulose particles were individually tracked among normal particles during compaction [24]. For the study of full-field local strain distributions, Nielsen et al [25] and Haldrup et al [26] have presented two similar methods by which a large number of artificially introduced markers are individually tracked in the bulk of solid aluminium samples in upsetting tests.…”
Section: Strain Measurements Using X-ray Tomographymentioning
confidence: 99%
“…In neither case was the resolution of the method clearly stated, but in the case of Ohgaki et al [23], spatial resolution appears to be on the order of some micrometers, albeit with significant noise in the strain data. Similar methods, but based on an addition of artificial markers, have also been used to study powder compaction and mixing, where a small number of lead-acetate impregnated cellulose particles were individually tracked among normal particles during compaction [24]. For the study of full-field local strain distributions, Nielsen et al [25] and Haldrup et al [26] have presented two similar methods by which a large number of artificially introduced markers are individually tracked in the bulk of solid aluminium samples in upsetting tests.…”
Section: Strain Measurements Using X-ray Tomographymentioning
confidence: 99%
“…projections of a 3D object, CT allows for multiple projections of the object to be acquired in a manner such that individual cross sectional slices as well as the entire 3D structure can be reconstructed [166].…”
Section: X-ray Computed Tomographymentioning
confidence: 99%
“…Ideally, these are inline methods to remove issues related to extractive sampling and allow direct monitoring of the system using various sensors. Many technologies have been investigated, including near-infrared spectroscopy 1-3 , Raman spectroscopy 4 , magnetic resonance imaging 5 , radioactive tracers 6 , image analysis 7 , tomography 8 and acoustic emission monitoring 9,10 .…”
Section: Introductionmentioning
confidence: 99%