2014
DOI: 10.1007/s00216-014-8388-1
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases

Abstract: The validation data showed no significant matrix effects and no ion suppression has been 7 observed in serum and urine. Mean intraday accuracy and precision for LSD were 101% and 8 6.84%, in urine samples and 97.40% and 5.89% in serum, respectively. For O-H-LSD the 9 respective values were 97.50% and 4.99% in urine and 107% and 4.70% in serum. Mean interday 10 accuracy and precision for LSD were 100% and 8.26% in urine and 101% and 6.56% in serum. 11For O-H-LSD the respective values were 101% and 8.11% in urin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
36
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 37 publications
(38 citation statements)
references
References 18 publications
0
36
0
1
Order By: Relevance
“…The 0.5, 1.5, and 2.5 h samples were not collected in study 1. Blood samples were immediately centrifuged, and the plasma was rapidly stored at −20 °C and later analyzed using liquid-chromatography-tandem mass-spectrometry as previously reported (Dolder et al 2015a; Steuer et al 2016). Maximal plasma concentrations ( C max ) and total exposure (area under the plasma concentration-time curve [AUC]) were estimated using compartmental modeling in Phoenix WinNonlin 6.4 (Certara, Princeton, NJ, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The 0.5, 1.5, and 2.5 h samples were not collected in study 1. Blood samples were immediately centrifuged, and the plasma was rapidly stored at −20 °C and later analyzed using liquid-chromatography-tandem mass-spectrometry as previously reported (Dolder et al 2015a; Steuer et al 2016). Maximal plasma concentrations ( C max ) and total exposure (area under the plasma concentration-time curve [AUC]) were estimated using compartmental modeling in Phoenix WinNonlin 6.4 (Certara, Princeton, NJ, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Martin et al [14] investigated LSD and its metabolites in some suspected LSD intoxication cases, and LSD (below LOQ to 1.5 ng/ml) and O-H-LSD (0.8-2.3 ng/ml) were detected in samples from three suspects. Dolder et al [11] also analyzed some toxicological samples and identified LSD and O-H-LSD in urine at concentrations of 1.3 and 9.7 ng/ml, respectively. Urinary concentrations of LSD found in our authentic specimens are similar to those reported.…”
Section: Application Of the Developed Methods To Authentic Samplesmentioning
confidence: 96%
“…According to a study by Peel and Boynton, LSD and its metabolites were detectable in urine samples from patients receiving 300 g of LSD for 34-120 h [9]. Since simultaneous determination of the parent drug and its metabolites assist in the interpretation of analysis, recent studies have included both LSD and O-H-LSD as suitable biomarkers for LSD intake [10][11][12][13][14]. When the timely collection of urine from drug suspects is impossible, hair has been used as an alternative.…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation
“…The blood samples were immediately centrifuged, and the plasma was rapidly stored at -20°C and later at -80°C until analysis. LSD concentrations in plasma were determined using liquid-chromatography-tandem mass-spectrometry as reported in detail elsewhere (Dolder et al, 2015a; Steuer et al, 2016). The lower limit of quantification was 0.05 ng/ml (Dolder et al, 2015a).…”
Section: Methodsmentioning
confidence: 99%