2020
DOI: 10.1111/ics.12603
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a reversed‐phase high‐performance liquid chromatographic method for the quantitation and stability of α‐lipoic acid in cosmetic creams

Abstract: Objective To develop and validate a simple reversed‐phase HPLC method for the quantitation and evaluation of stability of α‐lipoic acid in cosmetics, according to International Conference on Harmonization (ICH) Guidelines. Methods The chromatography was performed on a reversed‐phase Luna C18, analytical column (150 × 4.6 mm id, 5 μm particle size) with a mobile phase of potassium dihydrogen phosphate (pΗ 4.5; 0.05 M) and acetonitrile (60:40, v/v) and a flow rate of 1.0 mL min−1 with UV detection at 340 nm. Acc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 33 publications
(33 reference statements)
0
3
0
Order By: Relevance
“…HPLC is considered the most appropriate method for detecting TA [ 16 ]. Some methods have been reported to detect TA by LC [ 16 17 18 19 20 21 22 23 ]. The disadvantages of the previously reported methods include elaborate solid-phase extraction or derivatization steps [ 20 23 ], long run times (5–15 minutes) [ 16 17 19 ], and relatively poor sensitivity (0.13–5 μg/mL) [ 18 21 22 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…HPLC is considered the most appropriate method for detecting TA [ 16 ]. Some methods have been reported to detect TA by LC [ 16 17 18 19 20 21 22 23 ]. The disadvantages of the previously reported methods include elaborate solid-phase extraction or derivatization steps [ 20 23 ], long run times (5–15 minutes) [ 16 17 19 ], and relatively poor sensitivity (0.13–5 μg/mL) [ 18 21 22 ].…”
Section: Introductionmentioning
confidence: 99%
“…Some methods have been reported to detect TA by LC [ 16 17 18 19 20 21 22 23 ]. The disadvantages of the previously reported methods include elaborate solid-phase extraction or derivatization steps [ 20 23 ], long run times (5–15 minutes) [ 16 17 19 ], and relatively poor sensitivity (0.13–5 μg/mL) [ 18 21 22 ]. Considering the limitations of these previous methods, a faster, simpler, and more sensitive detection method for duloxetine and TA is needed.…”
Section: Introductionmentioning
confidence: 99%
“…Numerous analytical techniques have been used to quantify cosmetic ingredients through high-performance liquid chromatography (HPLC), such as HPLC coupled with other detectors, including ultraviolet (UV) detectors, mass spectrometers, and diode array detectors (DADs) (Papageorgiou et al, 2020). However, high-performance liquid chromatography with a diode array detector (HPLC-DAD) is highly recommended for analyzing herbal combinations because it offers 3D analyses and a wide array of mobile phases while being more affordable and resistant to contamination.…”
mentioning
confidence: 99%