2010
DOI: 10.1016/j.jchromb.2010.07.011
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a nylon6 nanofibers mat-based SPE coupled with HPLC method for the determination of docetaxel in rabbit plasma and its application to the relative bioavailability study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
6
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 34 publications
(46 reference statements)
1
6
0
Order By: Relevance
“…To date, the general analytic method for DTX in biological matrices is HPLC [12,[14][15][16][17] and liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) [18][19][20][21][22][23][24][25]. The lower limit of quantitation (LLOQ) of HPLC with UV detection assays for DTX analysis has been reported to be 2.5-12.5 ng/ml in plasma [12,[14][15][16][17]. Similar LLOQ of HPLC method was also achieved in our laboratory.…”
Section: Introductionsupporting
confidence: 73%
See 1 more Smart Citation
“…To date, the general analytic method for DTX in biological matrices is HPLC [12,[14][15][16][17] and liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) [18][19][20][21][22][23][24][25]. The lower limit of quantitation (LLOQ) of HPLC with UV detection assays for DTX analysis has been reported to be 2.5-12.5 ng/ml in plasma [12,[14][15][16][17]. Similar LLOQ of HPLC method was also achieved in our laboratory.…”
Section: Introductionsupporting
confidence: 73%
“…One potential problem with the use of lower DTX dose is the difficulty in determining drug levels in plasma over a time frame that is necessary for the accurate assay of pharmacokinetic parameters. To date, the general analytic method for DTX in biological matrices is HPLC [12,[14][15][16][17] and liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) [18][19][20][21][22][23][24][25]. The lower limit of quantitation (LLOQ) of HPLC with UV detection assays for DTX analysis has been reported to be 2.5-12.5 ng/ml in plasma [12,[14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…There have been several other reports on the use of nylon 6 nanofibers packed in the same format [70][71][72][73][74]. Similar to the first report by Xu and co-workers [69], all these reports seem to have focussed on demonstrating the feasibility of using electrospun nylon 6 nanofibers as a SPE sorbent material.…”
Section: Nylon Type Spe Devicesmentioning
confidence: 80%
“…Electrospinning is the most frequently used method to prepare nanobers. Some researchers, [16][17][18][19] including our group, [20][21][22][23][24] have explored the application of electrospun nanobers as SPE sorbents. As shown in our previous studies, electrospun nanobers have a high surface-to-volume ratio and length-to-diameter ratio, leading to a larger specic surface area and more active sites for adsorption.…”
Section: Introductionmentioning
confidence: 99%