Development and validation of a solid-phase extraction and gas chromatography–tandem mass spectrometry method for the determination of isopropyl-9H-thioxanthen-9-one in carton packaged milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(16 citation statements)
references
References 7 publications
0
14
0
Order By: Relevance
“…A few methods based on LC in combination with UV detection (Papilloud et al 2002;Sanches-Silva et al 2008a, 2008b, 2009 or even fluorescence detection have also been reported (Morlock & Schwak 2006;Sagratini et al 2008). However, LC-MS/MS has gained popularity (Sagratini et al 2006;Bagnati et al 2007;Gil-Vergara et al 2007;Sun et al 2007;Allegrone et al 2008;Gallart-Ayala et al 2008, 2011Sanches-Silva et al 2008;Shen et al 2009). A comparison between GC and LC has shown, however, that both techniques are adequate: LC gives a lower LOQ while the repeatability is comparable (Gil-Vergara et al 2007).…”
Section: Introductionmentioning
confidence: 95%
“…A few methods based on LC in combination with UV detection (Papilloud et al 2002;Sanches-Silva et al 2008a, 2008b, 2009 or even fluorescence detection have also been reported (Morlock & Schwak 2006;Sagratini et al 2008). However, LC-MS/MS has gained popularity (Sagratini et al 2006;Bagnati et al 2007;Gil-Vergara et al 2007;Sun et al 2007;Allegrone et al 2008;Gallart-Ayala et al 2008, 2011Sanches-Silva et al 2008;Shen et al 2009). A comparison between GC and LC has shown, however, that both techniques are adequate: LC gives a lower LOQ while the repeatability is comparable (Gil-Vergara et al 2007).…”
Section: Introductionmentioning
confidence: 95%
“…As in liquid chromatography, different detectors can be used with this technique, and the mass detector is the most commonly used (GC-MS), 16,22,24,28,36,[44][45][46][47][48][49] although in this case the use of mass-mass tandem is not very common. 50 The chromatographic separation was achieved with a low polar capillary column: HP-5 (Agilent s ) ((5%-phenyl)-methylpolysiloxane) (i.d., 30 mÂ0.32 mm and film thickness, 0.25 mm). The system was operated in splitless mode, with the oven temperature programmed to increase from 100 to 300 1C, and the detector temperature was set at 250 1C.…”
Section: Gas Chromatography (Gc)mentioning
confidence: 99%
“…Allegrone et al developed a method for determining ITX in milk. 50 For the extraction procedure, two alternative methods were assayed. In the first method, the milk was mixed with ethanol and water and extracted with SPE; in the second option, an alkaline hydrolysis was carried out previous to the SPE.…”
Section: Gas Chromatography (Gc)mentioning
confidence: 99%
“…Extrelut ® 20, Extrelut ® 3 and Extrelut ® 1 columns were purchased from Merck (Darmstadt, Germany). 1,4-Dioxane, (±)-2-phenyl-1-propanol, 2,2′-dithiodibenzoic acid, acetic anhydride, anhydrous aluminium chloride, benzoyl peroxide, bromine, copper(I) bromide, N-bromosuccinimide (NBS), m-chloroperbenzoic acid (mCPBA) (purity: 70%), (diacetoxyiodo)benzene, dichloroethane (DCE), N,N-dimethylformamide (DMF), glacial acetic acid, reduced glutathione (GSH), 2-ITX (as a mixture of 2-and 4-isomers; cLogP: 5.33 ± 0.27 calculated using Advanced Chemistry Development Software version 9.04) (Allegrone et al, 2008), phosphorus tribromide, potassium t-butylate, sulfuryl chloride, thionyl chloride, and triphenylphosphine were used without further purification and were purchased from Sigma-Aldrich. When needed, the reactions were performed in oven-dried glassware under a positive pressure of dry N 2 .…”