2022
DOI: 10.1007/s10337-022-04160-0
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of a Simple, Selective, and Accurate Reversed-Phase Liquid Chromatographic Method with Diode Array Detection (RP-HPLC/DAD) for the Simultaneous Analysis of 18 Free Amino Acids in Topical Formulations

Abstract: Even though there are reported methods for the quantification of free amino acids (FAAs) in biological products, no work has been done on the analysis of these substances in formulations. Moreover, further research is required as the reported methods do not fulfill analytical method requirements. The objective of this study was, therefore, to develop and validate a rapid, reliable, and appropriate RP-HPLC/DAD method for the simultaneous determination of 18 FAAs (l-Ala, l-Arg, l-Asn, l-Asp, l-Gln, l-Glu, l-Gly,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…The acceptance criterion for this test was % interference of less than 5 at the retention time of the respective analytics. 12,13,19…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The acceptance criterion for this test was % interference of less than 5 at the retention time of the respective analytics. 12,13,19…”
Section: Methodsmentioning
confidence: 99%
“…The acceptance criterion for this test was % interference of less than 5 at the retention time of the respective analytics. 12,13, 19 3.4.4.2 Linearity and limit of detection and limit of quantication. Linearity was evaluated by the least-squares linear regression analysis by building a calibration curve according to the procedure described in section 2.4.3.…”
Section: Nanoparticles Preparationmentioning
confidence: 99%
“…From (Fig. 3) shows that the analytical method gives a proportional linear response to the variation of analyte concentration which is indicated by the value of R 2 : 0.9998 with the regression equation y = 34706x + 83316 [24][25][26][27].…”
Section: Selectivitymentioning
confidence: 97%
“…36,57 For example, chromatographic methods are time-consuming and need advanced derivatization techniques. 58,59 Electrochemical procedures are constrained by molecular interference, and the detection of the biomolecules is sometimes hindered by photobleaching, which is a typical occurrence among uorescent probes. [60][61][62] Colorimetric tests are particularly notable among these approaches due to their inherent simplicity, high sensitivity, and cost-effectiveness.…”
Section: Introductionmentioning
confidence: 99%