2015
DOI: 10.1016/j.medengphy.2014.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
86
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 122 publications
(93 citation statements)
references
References 15 publications
3
86
0
Order By: Relevance
“…bed-or wheel chair-ridden patients) as well as for prosthetics wearers where optimising comfort at the stump-prosthetic interface and preventing pressure ulcers is critical [17,48,49]. These experimental techniques and tools offer vast opportunities to be complemented by computational studies to gain a more mechanistic understanding of the interplay between the physical factors that contribute to primary skin injuries and that can ultimately evolve into more serious conditions such as chronic wounds [5,9,50].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…bed-or wheel chair-ridden patients) as well as for prosthetics wearers where optimising comfort at the stump-prosthetic interface and preventing pressure ulcers is critical [17,48,49]. These experimental techniques and tools offer vast opportunities to be complemented by computational studies to gain a more mechanistic understanding of the interplay between the physical factors that contribute to primary skin injuries and that can ultimately evolve into more serious conditions such as chronic wounds [5,9,50].…”
Section: Discussionmentioning
confidence: 99%
“…12 illustrate how the risk of damage initiation (correlated with high shear stress) varies according to the contact conditions at specific topographic and internal microstructural features of the skin and how far an "idealised" distribution of shear stress might be from that naturally occurring in real in vivo conditions. To date, experimental studies have analysed interfacial shear stress as a surrogate in vivo measure of the risk of developing skin injuries [16][17][18]. Nevertheless, these studies do not provide a quantitative insight into how these stresses are transmitted from the surface to the deeper layers of the skin.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…see [67]) and printable sensor designs have also been proposed (e.g. [68]). Motion capture systems may also be employed to study and capture dynamic loading data which may serve as input for load evaluation and validation.…”
Section: Discussionmentioning
confidence: 99%
“…25 72 74 90 96 108 The skin suffers from abrasion, adding to the discomfort and potential for infection. 108 These problems persist in 20% to 55% of LL amputees no matter how good we optimize the socket design.…”
Section: Introductionmentioning
confidence: 99%