2023
DOI: 10.2139/ssrn.4331110
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Development and Validation of a Rapid and Sensitive Lc-Ms/Ms Approach for Alkaloids Testing in Different Lupin Species

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 0 publications
0
5
1
Order By: Relevance
“…In contrary to what was reported by Khedr et al (2023), the extraction method (70/30 methanol/water) resulted in little adverse matrix effects and satisfactory matrix recoveries, with average recoveries within the range of 70% and 120%. An overview of average recoveries at three concentration levels is given in S13.…”
Section: Methods Validationcontrasting
confidence: 91%
“…In contrary to what was reported by Khedr et al (2023), the extraction method (70/30 methanol/water) resulted in little adverse matrix effects and satisfactory matrix recoveries, with average recoveries within the range of 70% and 120%. An overview of average recoveries at three concentration levels is given in S13.…”
Section: Methods Validationcontrasting
confidence: 91%
“…The UPLC HSS T3 column resulted in being the suitable choice for this application as it is a low ligand density C18 column that shows enhanced retention of polar compounds and metabolites by reversed phase liquid chromatography, and displays a balanced retention of polar and hydrophobic molecules [51,52]. Moreover, it contributed to a time of analysis of 10.5 min, which is relatively short compared to previously described runs lasting more than 30 min, and it is comparable to the shorter times of 6 min runs performed by Khedr et al on LC-MS/MS [53][54][55]. The precision of the method for the measurement of gramine was assessed on pooled seeds of lupin.…”
Section: Discussionmentioning
confidence: 73%
“…The most recent studies suggest water/acetonitrile extraction followed by an LC-MS/MS analysis. This method reports linearity in the range of 0.55–55 mg/kg, an estimated accuracy of 93% and a relative standard deviation ((RSD) < 3.6%) [ 55 ]. Concerning the methods’ sensitivities, Ganzera et al presented LOD values ranging from 24.575 to 129.93 pmol/μL [ 63 ] for gramine and other alkaloids present in lupin (such as 13α-Hydroxylupanine and sparteine).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations