2015
DOI: 10.1016/j.ijrefrig.2015.05.016
|View full text |Cite
|
Sign up to set email alerts
|

Development and performance mapping of a multi-ejector expansion work recovery pack for R744 vapour compression units

Abstract: Development and performance mapping of a multi-ejector expansion work recovery pack for R744 vapour compression units, AbstractA multi-ejector expansion pack, intended as a substitute for a standard high-pressure electronic expansion valve (HPV), was designed, manufactured and experimentally investigated. Four different ejector cartridges were sized to enable a discrete opening characteristic with a binary profile for a parallel-compression R744 system. The system is rated for 70 kW at a 35 °C gas cooler outle… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
77
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 94 publications
(85 citation statements)
references
References 18 publications
1
77
0
Order By: Relevance
“…These parameters were set to represent the most typical operating conditions of supermarket refrigeration units operating under warm climate conditions (Banasiak et al, 2015;Hafner et al, 2014). The values in this table are sorted in ascending order of the absolute pressure at the motive nozzle.…”
Section: Mathematical Model and Computational Proceduresmentioning
confidence: 99%
“…These parameters were set to represent the most typical operating conditions of supermarket refrigeration units operating under warm climate conditions (Banasiak et al, 2015;Hafner et al, 2014). The values in this table are sorted in ascending order of the absolute pressure at the motive nozzle.…”
Section: Mathematical Model and Computational Proceduresmentioning
confidence: 99%
“…1. The more detailed information about the refrigeration unit are presented in the paper of Banasiak et al (2015).…”
Section: Measurementsmentioning
confidence: 99%
“…The range of considered inlet parameters was typical for ejectors operating in refrigeration installations of supermarkets (Hafner et al (2014), Banasiak et al (2015)). …”
Section: Hem Accuracy For Sub-and Supercritical Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…al. [9] studied the multi ejector expansion system for R744 vapour compression units on system rated for 70kW at 35 degree Celsius outlet temperature of gas cooler and -3 degree Celsius of evaporator temperature for four cartridge sized for ejectors system and this system was analyzed & verified experimentally. Multi ejector block system retains the dynamic operational characteristics and precise control of discharge pressure with load variations and atmospheric conditions.…”
Section: R Lazzarinet Al[4]mentioning
confidence: 99%