2018
DOI: 10.3390/s18041056
|View full text |Cite
|
Sign up to set email alerts
|

Development and On-Field Testing of Low-Cost Portable System for Monitoring PM2.5 Concentrations

Abstract: Recent developments in the field of low-cost sensors enable the design and implementation of compact, inexpensive and portable sensing units for air pollution monitoring with fine-detailed spatial and temporal resolution, in order to support applications of wider interest in the area of intelligent transportation systems (ITS). In this context, the present work advances the concept of developing a low-cost portable air pollution monitoring system (APMS) for measuring the concentrations of particulate matter (P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
30
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(34 citation statements)
references
References 29 publications
(29 reference statements)
2
30
0
2
Order By: Relevance
“…China [17] (Figure 1). The technology is based on laser diffraction theory, where particle density distribution is specified from the light intensity distribution patterns [21,29]. The sensor contains a digital output and a built-in fan ( Figure 2), which can measure the particle density distribution between 0.3 to 10 μm in the air.…”
Section: Nova Pm Sensor Sds011mentioning
confidence: 99%
“…China [17] (Figure 1). The technology is based on laser diffraction theory, where particle density distribution is specified from the light intensity distribution patterns [21,29]. The sensor contains a digital output and a built-in fan ( Figure 2), which can measure the particle density distribution between 0.3 to 10 μm in the air.…”
Section: Nova Pm Sensor Sds011mentioning
confidence: 99%
“…To the best of our knowledge, there no reports on the performance of the SDS011 sensor model in climates similar to Santiago, specifically, the Mediterranean type with dry summers. A few studies have assessed the performance of the SDS011 in humid subtropical climates, for example, in Thessaloniki, Greece (Genikomsakis et al 2018) and Florence, Italy (Cavaliere et al 2018). In both of these locations, R 2 above 0.85 was observed for the correlations between the PM 2.5 averages informed by the SDS011 and standard optical instruments.…”
Section: Accuracy Of Rh Sensor Measurements Compared To Reference Valuesmentioning
confidence: 99%
“…However, recently, inexpensive (<$300) particulate matter (PM) monitors (PM) have been introduced for home usage in South Korea. These devices can provide PM distribution patterns at high temporal and spatial resolution [3][4][5] which is a substantial improvement on establishing a pollution monitoring networking system as well as environmental epidemiologic study [6], as compared to traditional approaches that relied on relatively small number of ground-based fixed national air monitoring stations or mobile sampling techniques.…”
Section: Introductionmentioning
confidence: 99%