1988
DOI: 10.1097/00003086-198807000-00013
|View full text |Cite
|
Sign up to set email alerts
|

Development and First Experience with an Uncemented Press-Fit Cup

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
6

Year Published

1993
1993
2013
2013

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(19 citation statements)
references
References 0 publications
0
13
0
6
Order By: Relevance
“…It has been suggested apical gaps indicate a strong peripheral interference fit, which reduces micromotion and allows osteointegration to occur [16,18]. In support of this view, apical interference gaps have been associated with less component migration and 100% gap healing [18].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It has been suggested apical gaps indicate a strong peripheral interference fit, which reduces micromotion and allows osteointegration to occur [16,18]. In support of this view, apical interference gaps have been associated with less component migration and 100% gap healing [18].…”
Section: Discussionmentioning
confidence: 99%
“…Concerns exist about incomplete seating leading to reduced bony ingrowth and acetabular failure [12]. Recommendations for the size of underream in acetabular press-fit fixation range from 1 to 3 mm [1,3,15,16,24]. A 2-mm underream has been recommended for use in Birmingham Hip TM Resurfacing (BHR TM ; Smith & Nephew Inc, Memphis, TN, USA) [21].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In der Literatur werden bipolare Pfannen, ovaläre oder andere lang gestreckte Implantate, zementierte Pfannen unter Verwendung des "impaction bone grafting", die Kombination mit strukturierten Allografts, die Verwendung von Stützringen, die Sockelpfanne sowie die Individualprothese genannt [4,9,11].…”
Section: Vorbemerkungenunclassified
“…Cette approche mEcanique de la stabilitE ?~ long terme ne laisse place qu'~ deux alternatives, une stabilitE mEcanique initiale parfaite et un effet de surface autorisant une fixation biologique secondaire 6tant des principes fondamentaux: -L'emploi d'un implant isodlastique qui se dEforme sous l'effet de la charge et suit la ddformation du cotyle osseux [ 19,20]; cette proposition faite par certains auteurs utilisant un matdriau plus 61as-tique que le chrome-cobalt avec un anneau fendu ?~ sa pattie infdrieure au niveau de l'6chancrure et mis en press-fit, est une vole intdressante de recherche; deux objections peuvent atre toutefois soulevdes: l'absence de neutralisation des forces tangentielles ?~ l'interface laissant ainsi ?a la seule rdhabitation le r61e de force de cohdsion et l'inconnue que reprdsente le devenir de l'insert de polydthyRne dans un anneau ddformable.…”
Section: Commentairesunclassified