2015 IEEE International Conference on Robotics and Automation (ICRA) 2015
DOI: 10.1109/icra.2015.7139500
|View full text |Cite
|
Sign up to set email alerts
|

Development and experimental validation of a force sensing needle for robotically assisted retinal vein cannulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(24 citation statements)
references
References 22 publications
0
24
0
Order By: Relevance
“…During needle insertion, many authors presented optical sensors to measure force or pressure information based on the varying intensity or phase from a light signal [ 63 , 64 , 93 , 94 , 96 , 97 ]. An optical sensor is able to acquire force with multiple DOFs and in high-intensity magnetic fields for imaging with high sensitivity, reproducibility and no hysteresis [ 136 ].…”
Section: Needle Insertion Force Measurementmentioning
confidence: 99%
“…During needle insertion, many authors presented optical sensors to measure force or pressure information based on the varying intensity or phase from a light signal [ 63 , 64 , 93 , 94 , 96 , 97 ]. An optical sensor is able to acquire force with multiple DOFs and in high-intensity magnetic fields for imaging with high sensitivity, reproducibility and no hysteresis [ 136 ].…”
Section: Needle Insertion Force Measurementmentioning
confidence: 99%
“…In this device, three FBG optic fibers are attached along the long axis of the surgical instrument [23,24]. Gijbels et al also presented a surgical instrument for eye surgery, implemented using FBG sensors [25]. Yokoyama et al presented an FBG embedded irrigated radiofrequency ablation catheter [26].…”
Section: Fiber-bragg Grating (Fbg)mentioning
confidence: 99%
“…To distinguish a venous puncture from retraction events, a threshold value (P) needs to be specified such that only a sufficiently sharp drop in force ( ) will be reported as a venous puncture. Identifying a proper threshold though requires careful tuning [ 24 ] and may differ depending on the local mechanistic properties of the inhomogeneous retinal tissue as well as the operator’s skill level. On the contrary, keeping track of both the force and position of the tool tip can give a more generalized and reliable prediction of the venous puncture without having to worry about the force derivative threshold.…”
Section: System Operationmentioning
confidence: 99%
“…Flexible prebent stainless steel microneedles, which are normally held straight inside a protective shaft to be more easily introduced into the eye, have been developed. When deployed, these microneedles assume the optimum angle as they approach the retinal surface [ 24 , 25 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation