2023
DOI: 10.3390/ijerph20032293
|View full text |Cite
|
Sign up to set email alerts
|

Development and Evaluation of Sedentary Time Cut-Points for the activPAL in Adults Using the GGIR R-Package

Abstract: The purpose of this study was to develop sedentary cut-points for the activPAL and evaluate their performance against a criterion measure (i.e., activPAL processed by PALbatch). Part 1: Thirty-five adults (23.4 ± 3.6 years) completed 12 laboratory activities (6 sedentary and 6 non-sedentary activities). Receiver operator characteristic (ROC) curves proposed optimal Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) cut-points of 26.4 mg (ENMO) and 30.1 mg (MAD). Part 2: Thirty-eight adults (22.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 36 publications
(61 reference statements)
0
2
0
Order By: Relevance
“…However, all raw data were processed using the same standard algorithm (i.e., VANE) by PAL Software Suite version 8 to extract the acceleration data. The raw accelerometer data (i.e., acceleration volume) were computed using PAL Software Suite version 8 (Pal Technologies Ltd., Glasgow, UK) [ 25 , 26 ]. In addition, study participants were instructed to use a web diary (web application) developed by us to record their bedtimes, wake times on workdays and off-days, the start of work, return home, and exercise.…”
Section: Methodsmentioning
confidence: 99%
“…However, all raw data were processed using the same standard algorithm (i.e., VANE) by PAL Software Suite version 8 to extract the acceleration data. The raw accelerometer data (i.e., acceleration volume) were computed using PAL Software Suite version 8 (Pal Technologies Ltd., Glasgow, UK) [ 25 , 26 ]. In addition, study participants were instructed to use a web diary (web application) developed by us to record their bedtimes, wake times on workdays and off-days, the start of work, return home, and exercise.…”
Section: Methodsmentioning
confidence: 99%
“…This data will be derived in R using the GGIR package 45 , 46 . Established cut points for raw acceleration data from the thigh will be applied in analyses 47 . Validation criteria for valid days is described above in the activPAL SB section.…”
Section: Methodsmentioning
confidence: 99%