2011
DOI: 10.1016/j.atmosenv.2011.02.009
|View full text |Cite
|
Sign up to set email alerts
|

Development and evaluation of a method for hexavalent chromium in ambient air using IC-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
41
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(49 citation statements)
references
References 23 publications
6
41
2
Order By: Relevance
“…The chromatograms of the 1.0 ppb Cr external standard and a typical ambient PM sample are shown in Figures 1 and 2, respectively. The retention times of Cr (VI) and Cr(III) were 0.63-1.00 min and 2.20-2.81 min, respectively, under the conditions of our method for the measurement of Cr(VI) in ambient PM (Meng et al, 2011). The chromatograms showed that Cr(III) in the ambient PM samples extracted with DI-H 2 O was below detection limit.…”
Section: Resultsmentioning
confidence: 85%
See 3 more Smart Citations
“…The chromatograms of the 1.0 ppb Cr external standard and a typical ambient PM sample are shown in Figures 1 and 2, respectively. The retention times of Cr (VI) and Cr(III) were 0.63-1.00 min and 2.20-2.81 min, respectively, under the conditions of our method for the measurement of Cr(VI) in ambient PM (Meng et al, 2011). The chromatograms showed that Cr(III) in the ambient PM samples extracted with DI-H 2 O was below detection limit.…”
Section: Resultsmentioning
confidence: 85%
“…Prior to setup in the field, 10 mL each of 1 ng/mL 53 Cr (VI) and 1 ng/mL 50 Cr(III) were spiked on the filter. The sample extraction and analysis procedures were described in Meng et al (2011). The mass of Cr(VI) in the sample extract was determined by the external calibration curve and EPA method 6800, respectively.…”
Section: Sample Collection and Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…The use of speciated isotope dilution mass spectrometry (SIDMS) to study possible arsenic species inter-conversions occurring during the extraction is not applicable. [27][28][29] In the literature, the use of X-ray absorption near edge structure (XANES) spectroscopy as a benchmark for validation of extraction methods is oen reported. 29,30 XANES is a non-destructive element-specic technique for characterising electronic congurations of both amorphous and crystalline materials.…”
Section: Introductionmentioning
confidence: 99%