2011
DOI: 10.1016/j.jpba.2010.11.029
|View full text |Cite
|
Sign up to set email alerts
|

Development and evaluation of a multiple-plate fraction collector for sample processing: Application to radioprofiling in drug metabolism studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…Liquid scintillation counting (LSC) has been routinely used to analyze the total radioactivity of samples. HPLC with online radioactivity detection or fractionation with off-line radioactivity counting have been used for metabolite radio-profiling. , With these radiometric detection techniques, administration of radioactive doses in the range of 50 to 200 μCi (1.85 to 7.4 MBq) or higher generally provides the best opportunity to achieve adequate sensitivity for the plasma assessments. Over the last two decades, accelerator mass spectrometry (AMS) has been utilized in an increasing number of ADME studies to measure 14 C for PK of total DRM, to determine mass balance, and to generate 14 C-metabolite profiles.…”
Section: Other Scenariosmentioning
confidence: 99%
“…Liquid scintillation counting (LSC) has been routinely used to analyze the total radioactivity of samples. HPLC with online radioactivity detection or fractionation with off-line radioactivity counting have been used for metabolite radio-profiling. , With these radiometric detection techniques, administration of radioactive doses in the range of 50 to 200 μCi (1.85 to 7.4 MBq) or higher generally provides the best opportunity to achieve adequate sensitivity for the plasma assessments. Over the last two decades, accelerator mass spectrometry (AMS) has been utilized in an increasing number of ADME studies to measure 14 C for PK of total DRM, to determine mass balance, and to generate 14 C-metabolite profiles.…”
Section: Other Scenariosmentioning
confidence: 99%
“…Recently, a multi-microplate fraction collector has been evaluated which made it possible to collect fractions in up to 24 96-or 384-well plates without manual intervention. Combined with UPLC this system provided high-resolution radiochromatograms with minimum manual input [63]. Online radioflow detection (HPLC-RFD) also requires minimal manual input, but suffers from poor sensitivity due to the short residence times of the radioactive peaks in the detection cell [44].…”
Section: Review | Dubbelman Rosing Schellens and Beijnenmentioning
confidence: 99%
“…This direction maintains the conventional radioactive doses of around 100 µCi, but uses high-resolution and high-throughput techniques, such as the multi-microplate fraction collector combined with microplate scintillation counting for metabolite profiling [63], to reduce the labor intensity of a mass balance study. Regarding the detection of unknown metabolites, data mining methods that can be applied to mass spectrometry data have high potency, especially in combination with high-resolution mass data.…”
Section: Future Perspectivementioning
confidence: 99%
“…Because of the large number of wells per plate, it is widely used for combinatorial chemistry and high throughput screening. Coupled with various chemical analysis techniques, such as ultraviolet–visible spectroscopy, fluorescence spectroscopy, liquid chromatography (LC), capillary electrophoresis (CE), and mass spectrometry (MS), it is extensively used for enzyme-linked immunosorbent assays (ELISA), enzyme activity or inhibition assays, , and drug metabolism studies. , Compared to spectroscopy techniques, MS can offer direct qualification and quantification of a wide range of analytes, providing accurate and specific characterization to avoid false positive or negative results, and thereby is highly suitable for the studies of enzymatic assays, inhibitor screening assays, and drug metabolism assays. …”
mentioning
confidence: 99%