2012
DOI: 10.1063/1.4707046
|View full text |Cite
|
Sign up to set email alerts
|

Development and demonstration of a supercritical helium-cooled cryogenic viscous compressor prototype for the iter vacuum system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…The Penning gauge has been successfully used in similar configurations to discern gas composition in vacuum systems as it relates to fusion-based reactions and dynamics [11][12][13]. Previous testing [10] simply measured the internal pressure as the frozen deuterium would sublimate. Further analysis revealed that the regeneration pressure did not provide a consistent estimate due to temperature variation in the setup from test to test.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…The Penning gauge has been successfully used in similar configurations to discern gas composition in vacuum systems as it relates to fusion-based reactions and dynamics [11][12][13]. Previous testing [10] simply measured the internal pressure as the frozen deuterium would sublimate. Further analysis revealed that the regeneration pressure did not provide a consistent estimate due to temperature variation in the setup from test to test.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…While the prototype CVC single tube test assembly has been presented previously [10], a brief description is provided here in order to provide the appropriate context for the experimental results as well as present some of the modifications that have been made from the initial design. The prototype CVC single tube test assembly, which is shown in Fig.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…A helium coolant (supercritical helium or cold helium gas) flows through the outer annular pipe. A full description and visual depiction of the cryogenic fore pump can be found in our colleagues' publications [2,3]. Figure 1 shows a differential control volume of the CFP model.…”
Section: Introductionmentioning
confidence: 99%
“…At Oak Ridge National Lab, a prototype CFP has been built and tested [2,3], while efforts at the University of Wisconsin-Madison, have focused on the physical analysis and modeling. The experimental results provide a reference for the theoretical models, and the theoretical work can provide guidance for future experiments.…”
Section: Introductionmentioning
confidence: 99%