2016
DOI: 10.3389/fpsyt.2016.00130
|View full text |Cite
|
Sign up to set email alerts
|

Development and Clinical Evaluation of an mHealth Application for Stress Management

Abstract: A large number of individuals experience mental health disorders, with cognitive behavioral therapy (CBT) emerging as a standard practice for reduction in psychiatric symptoms, including stress, anger, anxiety, and depression. However, CBT is associated with significant patient dropout and lacks the means to provide objective data regarding a patient’s experience and symptoms between sessions. Emerging wearables and mobile health (mHealth) applications represent an approach that may provide objective data to t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
55
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(57 citation statements)
references
References 38 publications
1
55
0
1
Order By: Relevance
“…Currently, the efficacy of EMI applications is mostly evaluated based on patients' self-reports and thus not different from the evaluation of classical face-to-face therapies. In most cases, questionnaires or reports on mental health outcomes are filled in prior to and after the intervention (e.g., 27,28), sometimes with additional follow-up assessments (e.g., 19,29). While selfreports are necessary to gain insights into the subjective perception and evaluation of symptoms, they are potentially confounded by biases (30).…”
Section: Optimization Of Therapy Outcome Measuresmentioning
confidence: 99%
See 1 more Smart Citation
“…Currently, the efficacy of EMI applications is mostly evaluated based on patients' self-reports and thus not different from the evaluation of classical face-to-face therapies. In most cases, questionnaires or reports on mental health outcomes are filled in prior to and after the intervention (e.g., 27,28), sometimes with additional follow-up assessments (e.g., 19,29). While selfreports are necessary to gain insights into the subjective perception and evaluation of symptoms, they are potentially confounded by biases (30).…”
Section: Optimization Of Therapy Outcome Measuresmentioning
confidence: 99%
“…A small-sampled clinical EMI study on stress and anger management in veterans (27) used mobile cardiovascular and electrodermal measurements to indicate physiological stress. Both the control group (n = 6) and the experimental group (n = 10) received standard CBT for 8 to 10 weeks.…”
Section: Optimization Of Therapy Outcome Measuresmentioning
confidence: 99%
“…Briefly, baseline HR and EDA were used to normalize real-time HR and EDA data. Normalized data was then subjected to a 2-feature linear model classifier which audibly alerted the participant when ANS stress was observed [43]. Salivary cortisol indicative of HPA stress response was measured by standard ELISA (Salimetrics, Carlsbad CA intra-assay CV = 4.5%, inter-assay CV = 5.8%).…”
Section: Methodsmentioning
confidence: 99%
“…There is evidence for telemonitoring of cardiac implantable electronic devices (CIED) to improve the prognosis in patients with CIED, and remote multiparameter monitoring based on defibrillation devices has become a class II b recommendation in those subjects (2,3) . Telemedicine has also been shown to be helpful to manage psychological status in chronic diseases, and internet-mediated interventions are believed to be effective for depression and anxiety (1,4,5) . Mental disorders related to life with an implantable cardioverter-defibrillator (ICD) are a known and common problem (3) .…”
Section: Telemonitoring Cardiac Implantable Electronic Devices Psycmentioning
confidence: 99%
“…Telemedicine and e-health constitute a modern and quickly developing approach to health care provision (1) . There is evidence for telemonitoring of cardiac implantable electronic devices (CIED) to improve the prognosis in patients with CIED, and remote multiparameter monitoring based on defibrillation devices has become a class II b recommendation in those subjects (2,3) .…”
Section: Telemonitoring Cardiac Implantable Electronic Devices Psycmentioning
confidence: 99%