2017
DOI: 10.1088/1748-0221/12/09/p09008
|View full text |Cite
|
Sign up to set email alerts
|

Development and calibration of a new gamma camera detector using large square Photomultiplier Tubes

Abstract: Large area scintillation detectors applied in gamma cameras as well as Single Photon Computed Tomography (SPECT) systems, have a major role in in-vivo functional imaging. Most of the gamma detectors utilize hexagonal arrangement of Photomultiplier Tubes (PMTs). In this work we applied large square-shaped PMTs with row/column arrangement and positioning. The Use of large square PMTs reduces dead zones in the detector surface. However, the conventional center of gravity method for positioning may not introduce a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 17 publications
0
9
0
Order By: Relevance
“…Although the ProSPECT scanner used in this work, designed and built by our group, is not yet commercially available in many countries, its technical performance exhibited comparable performance in terms of sensitivity, spatial and energy resolution to other commercially available SPECT cameras. 25 Moreover, this study was conducted to investigate the potential of a novel deep learning-based low-dose/fast cardiac SPECT imaging, which is applicable on any SPECT camera offering sufficient flexibility for data acquisition. Hence, similar outcomes are expected when applying this approach on other commercial SPECT cameras.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the ProSPECT scanner used in this work, designed and built by our group, is not yet commercially available in many countries, its technical performance exhibited comparable performance in terms of sensitivity, spatial and energy resolution to other commercially available SPECT cameras. 25 Moreover, this study was conducted to investigate the potential of a novel deep learning-based low-dose/fast cardiac SPECT imaging, which is applicable on any SPECT camera offering sufficient flexibility for data acquisition. Hence, similar outcomes are expected when applying this approach on other commercial SPECT cameras.…”
Section: Discussionmentioning
confidence: 99%
“…MPI-SPECT imaging was performed on fixed 90°angle dual-head ProSPECT dedicated cardiac SPECT camera. 25 The ProSPECT detector is composed of Thallium-activated Sodium Iodide (NaI(Tl)) crystal having a size of 40 9 25 cm 2 and 9.5 mm thickness. A square array of PMTs (24 pcs, 76 9 76 mm) was optically coupled to a 20-mm thick fused-quartz light-guide using a silicon-based curing compound as optical glue.…”
Section: Image Acquisitionmentioning
confidence: 99%
See 1 more Smart Citation
“…A minimum of 10 k counts for each central pixel must be collected. These calibration methods have been described in our previous works [19].…”
Section: Calibrationmentioning
confidence: 99%
“…Anger logic, based on the center of gravity algorithm, is a well-known method but suffers from poor spatial resolution and strong FOV compression [14]. Different algorithms have been introduced to improve spatial resolution in gamma cameras [19][20][21][22]. Because we used square PMTs in our developed detector, the CSE method was chosen as the positioning method.…”
Section: Introductionmentioning