1990
DOI: 10.1002/jps.2600790313
|View full text |Cite
|
Sign up to set email alerts
|

Development and Application of a Radioimmunoassay for Fluphenazine Based on Monoclonal Antibodies and Its Comparison with Alternate Assay Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1990
1990
2000
2000

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Plasma levels of fluphenazine were measured using a radioimmunoassay (RIA) which was validated for specificity using gas chromatography mass spectroscopy (Midha et al 1980;McKay et al 1990). The sensitivity of the assay was 0.1 ng/ml and the coefficient of variation was 3%.…”
Section: Assay Techniquesmentioning
confidence: 99%
“…Plasma levels of fluphenazine were measured using a radioimmunoassay (RIA) which was validated for specificity using gas chromatography mass spectroscopy (Midha et al 1980;McKay et al 1990). The sensitivity of the assay was 0.1 ng/ml and the coefficient of variation was 3%.…”
Section: Assay Techniquesmentioning
confidence: 99%
“…The antibodies used in the RIAs of FLU-SO, 7-OH-FLU, and FLU-NO were polyclonal antibodies raised against suitable trifluoperazine sulfoxide, trifluoperazine 7-hydroxy, and prochlorperazine N 4 '-oxide hapten-BSA conjugate based immunogens in New Zealand white rabbits (Aravagiri et al 1984(Aravagiri et al , 1985(Aravagiri et al , 1986 The antibody used in the RIA of FLU was monoclonal and raised against a FLU hapten-thyroglobulin-based immunogen using hybridoma technique in mice as reported previously (McKay et al 1990).…”
Section: Antibodiesmentioning
confidence: 99%
“…All tissues were homogenized in 10 ml of ice-cold physiologic saline (150 mM NaCl). Suitably diluted aliquots of these homogenates were assayed for FLU, FLU-SO, 7-OH-FLU, and FLU-NO by sensitive and specific RIAs (Aravagiri et al 1990(Aravagiri et al , 1994aMidha et al 1988;McKay et al 1990). The lower limit of determination for all RIAs was 0.1 ng of analyte/ml.…”
Section: <1mentioning
confidence: 99%
“…Individual antibody characterization and RIA procedures are detailed elsewhere (Midha et al 1988;McKay et al 1990;Aravagiri et al 1990Aravagiri et al , 1994a. Sample extracts were assayed in triplicates in subdued light.…”
Section: Extraction Of Flu and Its Metabolitesmentioning
confidence: 99%