Development and application of a respiratory device on blood pressure in adults with high blood pressure

Abstract: Purpose The purpose of this study is to develop a prototype of a novel respiratory device that we validated and assessed clinically and examined the effect of prototype of respiratory device on blood pressure (BP). Methods Prototype of respiratory device (TU-Breath Training) was designed with pressure cuff and application software was created. The immediate effect of resisted breathing was determined in 20 adults with high BP (systolic BP ≥ 130 mmHg and diastolic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…The DGSB RCTs 7,17,19,21–26,29,32–36 showed a minimal and not statistically significant reduction in the post/change SBP of −2.13/−2.42 mmHg and in the post/change DBP of −0.93/−1.67 mmHg. Meta‐analyzes identified that the DGSB did not significantly reduce BP compared to the control.…”
Section: Discussionmentioning
confidence: 78%
See 1 more Smart Citation
“…The DGSB RCTs 7,17,19,21–26,29,32–36 showed a minimal and not statistically significant reduction in the post/change SBP of −2.13/−2.42 mmHg and in the post/change DBP of −0.93/−1.67 mmHg. Meta‐analyzes identified that the DGSB did not significantly reduce BP compared to the control.…”
Section: Discussionmentioning
confidence: 78%
“…The DGSB RCTs 7,17,19,[21][22][23][24][25][26]29,[32][33][34][35][36] showed a minimal and not statistically significant reduction in the post/change SBP of −2.13/ −2.42 mmHg and in the post/change DBP of −0.93/−1.67 mmHg.…”
Section: Discussionmentioning
confidence: 99%
“…A pressure sensor was connected to the respiration sensor, and the pressure value was sent to a smartphone via Bluetooth®. The pressure sensor and system have been described in detail elsewhere (Yuenyongchaiwat et al 2019).…”
Section: Methodsmentioning
confidence: 99%
“…Based on the findings of a previous study, we created a prototype respiratory training device (TU-Breath Training) that can be attached to the lower costal margin. Furthermore, training using the TU-breathe has been shown to reduce blood pressure in participants with hypertension (Yuenyongchaiwat et al 2019). Therefore, we aimed to design and develop a new version of our respiratory training device and explore its effects on cardiorespiratory performance (respiratory muscle strength and functional capacity) and dyspnea score in patients undergoing hemodialysis.…”
Section: Introductionmentioning
confidence: 99%