2017
DOI: 10.1101/171025
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Developing a 3- to 6-state EEG-based brain-computer interface for a robotic manipulator control

Abstract: Abstract-Recent developments in BCI techniques have demonstrated high-performance control of robotic prosthetic systems primarily via invasive methods. In this work we develop an electroencephalography (EEG) based noninvasive BCI system that can be used for a similar, albeit lower-speed robotic control, and a signal processing system for detecting user's mental intent from EEG data based on up to 6-state motor-imagery BCI communication paradigm. We examine the performance of that system on experimental data co… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2
2
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 83 publications
0
5
0
Order By: Relevance
“…In this work, we publish an EEG BCI dataset (Data Citation 1) collected during the development of a slow cortical potentials MI EEG BCI in Mishchenko et al 40 . The dataset contains 60 hours of EEG BCI recordings across 75 recording sessions of 13 participants, 60,000 mental imageries, and 4 BCI interaction paradigms, with multiple recording sessions and paradigms of the same individuals.…”
Section: Background and Summarymentioning
confidence: 99%
See 3 more Smart Citations
“…In this work, we publish an EEG BCI dataset (Data Citation 1) collected during the development of a slow cortical potentials MI EEG BCI in Mishchenko et al 40 . The dataset contains 60 hours of EEG BCI recordings across 75 recording sessions of 13 participants, 60,000 mental imageries, and 4 BCI interaction paradigms, with multiple recording sessions and paradigms of the same individuals.…”
Section: Background and Summarymentioning
confidence: 99%
“…The recording sessions in the dataset with the “Inter” identifier were collected using custom software that we call interactive interface, and is described in greater details in Mishchenko et al 40 . The key difference is that Matlab software directly interfaced with Neurofax software to accesses the EEG data in real time to enable real-time feedback to be given in a BCI system.…”
Section: Data Recordsmentioning
confidence: 99%
See 2 more Smart Citations
“…Regularly, digit from 1 to up 5 appears on each finger to guide the subject under tests to imagine the up and down finger flexion movements. At the same time, the EEG-1200 equipment captures and registers the corresponding signals via Neurofax recording software [34].…”
Section: The Project Datasetmentioning
confidence: 99%