2020
DOI: 10.1016/j.aca.2020.01.011
|View full text |Cite
|
Sign up to set email alerts
|

Deuterium analysis by inductively coupled plasma mass spectrometry using polyatomic species: An experimental study supported by plasma chemistry modeling

Abstract: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 53 publications
0
6
0
Order By: Relevance
“…Galbacs et al 85 used classical thermodynamics to predict the equilibrium concentration of polyatomic species formed from Ar, H, D and O in the ICP, with a view to the analytical determination of D by monitoring a polyatomic ion. They predicted that the species ArD + , OD + , HD + , and D 2 + (at m / z 42, 18, 3, and 4 respectively) were sufficiently present at T = 5000 K to make them useful for determination of D. After optimisation of the operating conditions, calibration curves were constructed for ions at m / z 4 and 42 using mixtures of D-depleted (with 1 ppm D) and D-enriched (99.96 atom% D) waters.…”
Section: Instrumentation Fundamentals and Chemometricsmentioning
confidence: 99%
“…Galbacs et al 85 used classical thermodynamics to predict the equilibrium concentration of polyatomic species formed from Ar, H, D and O in the ICP, with a view to the analytical determination of D by monitoring a polyatomic ion. They predicted that the species ArD + , OD + , HD + , and D 2 + (at m / z 42, 18, 3, and 4 respectively) were sufficiently present at T = 5000 K to make them useful for determination of D. After optimisation of the operating conditions, calibration curves were constructed for ions at m / z 4 and 42 using mixtures of D-depleted (with 1 ppm D) and D-enriched (99.96 atom% D) waters.…”
Section: Instrumentation Fundamentals and Chemometricsmentioning
confidence: 99%
“…Considering 3 H is toxic and volatile, the LIBS measurements of irradiated samples were all carried out in a static 45 Torr Ar environment. The 3 H studied here was produced via neutron irradiation of a 6 Li-enriched LiAlO 2 ceramic pellet which was surrounded by a Zircaloy-4 tube that acts as a 3 H getter. This Zircaloy-4 getter component is Ni-plated to prevent oxidation.…”
mentioning
confidence: 99%
“…[3][4][5] However, all of these techniques are laboratory-based and require extensive sample preparation. Mass spectrometry methods such as ICP-MS are capable of high precision measurements, 6 whereas other instruments, e.g., nanoscale SIMS 7 and APT, 5 can map isotopes with nanometer-scale spatial resolution. Some of these techniques are not useful for obtaining spatial information (e.g., ICP-MS).…”
mentioning
confidence: 99%
“…1,2 Several techniques such as Raman spectroscopy, quadrupolar mass spectrometry, and gas chromatography were developed for this analysis. 3–5 Among them, gas chromatography stands out due to its accuracy of analysis and simplicity of operation and construction. 6,7…”
mentioning
confidence: 99%
“…1,2 Several techniques such as Raman spectroscopy, quadrupolar mass spectrometry, and gas chromatography were developed for this analysis. [3][4][5] Among them, gas chromatography stands out due to its accuracy of analysis and simplicity of operation and construction. 6,7 Gas chromatography always relies on column stationary phase materials, which generally include glass microspheres, 8 alumina, 9 metal organic framework composites, 10 and membranes.…”
mentioning
confidence: 99%