Determining Aggregate Frost Susceptibility with the Tube Suction Test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
3
3
2

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…In general, higher water contents after freezing were associated with greater amounts of frost heave, an observation also illustrated in Figure 8. However, some specimens with relatively high water contents did not exhibit substantial heave, presumably because of the presence of salts in the pore water that depressed the freezing point (13). In several such cases, limited electrical conductivity measurements obtained during the conditioning period confirmed this hypothesis.…”
Section: Test Resultsmentioning
confidence: 94%
“…In general, higher water contents after freezing were associated with greater amounts of frost heave, an observation also illustrated in Figure 8. However, some specimens with relatively high water contents did not exhibit substantial heave, presumably because of the presence of salts in the pore water that depressed the freezing point (13). In several such cases, limited electrical conductivity measurements obtained during the conditioning period confirmed this hypothesis.…”
Section: Test Resultsmentioning
confidence: 94%
“…The air temperature in the environmental room and the water temperature in the bath were checked regularly, with the latter being consistently around 5°C for the duration of the testing. Recent frost heave tests of similar materials suggested that the specimens likely developed a constant temperature profile within the first 50 h, with the surface temperature just under the cover cooling to only about −3°C (19). Thus, the temperature gradient in each specimen was about 0.4°C/cm.…”
Section: Methodsmentioning
confidence: 96%
“…Aggregates having final dielectric values between 10 and 16 are expected to be marginally moisture susceptible. Continuing laboratory tests have confirmed a positive relationship between these moisture-susceptibility classifications and the strength-loss and frost-heave characteristics of granular materials (5,10).…”
Section: Figure 2 Orientational Polarization (8) Figure 3 Typical Tst Arrangementmentioning
confidence: 95%
“…Important factors for determining moisture susceptibility include soil suction, permeability, and the state of bonding of water that accumulates within the aggregate matrix (5).…”
Section: Moisture Susceptibilitymentioning
confidence: 99%