1995
DOI: 10.4141/cjss95-067
|View full text |Cite
|
Sign up to set email alerts
|

Détermination par méthode électromagnétique de la concentration en sel d’un sol irrigué

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…The CS60 instrument has a 27 960 Hz frequency, a 0.6 m intercoil spacing and is normally used in VCP (horizontal dipoles) coil configuration; when necessary it can be used in HCP (vertical dipoles) coil configuration to increase the investigation ability for deep layers. Its characteristics, coil orientation and spacing, were originally designed for irrigated salted soil studies (Job et al, 1995) and not for archaeology (for which PERP configuration would be better). Measurements can be achieved either point by point or by continuously pulling the apparatus on a cart (Figure 3).…”
Section: Test Site Control Data and Apparatusmentioning
confidence: 99%
See 1 more Smart Citation
“…The CS60 instrument has a 27 960 Hz frequency, a 0.6 m intercoil spacing and is normally used in VCP (horizontal dipoles) coil configuration; when necessary it can be used in HCP (vertical dipoles) coil configuration to increase the investigation ability for deep layers. Its characteristics, coil orientation and spacing, were originally designed for irrigated salted soil studies (Job et al, 1995) and not for archaeology (for which PERP configuration would be better). Measurements can be achieved either point by point or by continuously pulling the apparatus on a cart (Figure 3).…”
Section: Test Site Control Data and Apparatusmentioning
confidence: 99%
“…Its characteristics, coil orientation and spacing, were originally designed for irrigated salted soil studies (Job et al, 1995) and not for archaeology (for which PERP configuration would be better). Measurements can be achieved either point by point or by continuously pulling the apparatus on a cart (Figure 3).…”
Section: Test Site Control Data and Apparatusmentioning
confidence: 99%
“…The CS60 is a Slingram geometry apparatus working in the frequency domain (Job et al , ). It comprises two coplanar coils, separated by 0.6 m. Its working frequency is 27 960 Hz.…”
Section: Methodsmentioning
confidence: 99%
“…These experiments were achieved using the CS60 apparatus, a prototype device developed and manufactured in our lab (Job et al, 1995;Thiesson et al, 2009), in both VCP and VVCP configurations and a reference survey in each case.…”
Section: Field Experimentsmentioning
confidence: 99%