Determination of Vanadium, Chromium and Molybdenum by Atomic Absorption Spectrometry Using a Graphite Furnace Coated with Boron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
10
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…Boric acid was also added to each sample to further limit formation of vanadium carbide that could reduce the sensitivity of the method. 12 Method blanks and Standard Reference Materials SRM 1643d, Trace Elements in Water, SRM 1486, Bone Meal, and SRM 1566b, Oyster Tissue (National Institute of Standards and Technology, Gaithersburg, MD) were used for method quality control and to assess vanadium recovery. Femur vanadium concentrations were compared to those previously reported in the rat.…”
Section: Local Vanadium Quantificationmentioning
confidence: 99%
“…Boric acid was also added to each sample to further limit formation of vanadium carbide that could reduce the sensitivity of the method. 12 Method blanks and Standard Reference Materials SRM 1643d, Trace Elements in Water, SRM 1486, Bone Meal, and SRM 1566b, Oyster Tissue (National Institute of Standards and Technology, Gaithersburg, MD) were used for method quality control and to assess vanadium recovery. Femur vanadium concentrations were compared to those previously reported in the rat.…”
Section: Local Vanadium Quantificationmentioning
confidence: 99%
“…[7][8][9] Although a combination of using chemical modifiers and pre-coating the graphite furnace can improve boron absorbance measurements, the advantages of using GF-AAS, such as its relative simplicity and the speed at which it can be used to analyze samples, are lost when a pre-coating treatment is required. New chemical modifiers that can stabilize boron reactions in the graphite furnace without requiring the furnace to be pre-coated are required.…”
Section: Introductionmentioning
confidence: 99%
“…The loss of vanadium in graphite furnace during the atomization process has been considered to be due to the formation of its carbide. Therefore, for the determination of vanadium by a graphite furnace AAS, the uses of a pyrolytic graphite tube and tubes coated with such elements as tungsten, 9 zirconium, 10 lanthanum 11 and boron, 12 have been recommended. In this paper, the direct determination method of the vanadium in the heavy oil was studied by utilizing graphite tubes coated with tungsten.…”
Section: Introductionmentioning
confidence: 99%