2011
DOI: 10.1002/bmc.1730
|View full text |Cite
|
Sign up to set email alerts
|

Determination of unbound prednisolone, prednisone and cortisol in human serum and saliva by on‐line solid‐phase extraction liquid chromatography tandem mass spectrometry and potential implications for drug monitoring of prednisolone and prednisone in saliva

Abstract: Prednisolone (PLN) and prednisone (PN) are widely used glucocorticoids. Drug monitoring of PLN and PN is not routinely done owing to the need for multiple blood sampling and challenging measurement of unbound PLN and PN in blood. Here we present a robust method for quantification of cortisol, PLN and PN in serum, ultrafiltrate and saliva by on-line solid-phase extraction LC-MS/MS. The method is linear for the three analytes over the range of 6-1400 nmol/L for serum and 2-450 nmol/L for ultrafiltrate and saliva… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 32 publications
0
15
0
Order By: Relevance
“…Based on previous reports, a specificity test was performed to evaluate interference by prednisolone (molecular formula C 21 H 28 O 5 ) and prednisone (molecular formula C 21 H 26 O 5 ) on levels of CORTol (molecular formula C 21 H 30 O 5 ) and CORTone (molecular formula C 21 H 28 O 5 ) . Potential interference derives from prednisolone and CORTone being isobars, prednisolone and prednisone having naturally occurring M + 2 isotopes with the same molecular weight as CORTol and CORTone, respectively, and, given the chemical similarity of all these molecules, chromatographic coelution is possible . In the specificity test, an aqueous solution of prednisolone and prednisone at 400 nmol/L and 250 nmol/L, respectively, was used to simulate the maximum levels expected in human oral fluid following administration of 80 mg prednisolone (the maximum therapeutic dose) …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on previous reports, a specificity test was performed to evaluate interference by prednisolone (molecular formula C 21 H 28 O 5 ) and prednisone (molecular formula C 21 H 26 O 5 ) on levels of CORTol (molecular formula C 21 H 30 O 5 ) and CORTone (molecular formula C 21 H 28 O 5 ) . Potential interference derives from prednisolone and CORTone being isobars, prednisolone and prednisone having naturally occurring M + 2 isotopes with the same molecular weight as CORTol and CORTone, respectively, and, given the chemical similarity of all these molecules, chromatographic coelution is possible . In the specificity test, an aqueous solution of prednisolone and prednisone at 400 nmol/L and 250 nmol/L, respectively, was used to simulate the maximum levels expected in human oral fluid following administration of 80 mg prednisolone (the maximum therapeutic dose) …”
Section: Methodsmentioning
confidence: 99%
“…Potential interference derives from prednisolone and CORTone being isobars, prednisolone and prednisone having naturally occurring M + 2 isotopes with the same molecular weight as CORTol and CORTone, respectively, and, given the chemical similarity of all these molecules, chromatographic coelution is possible . In the specificity test, an aqueous solution of prednisolone and prednisone at 400 nmol/L and 250 nmol/L, respectively, was used to simulate the maximum levels expected in human oral fluid following administration of 80 mg prednisolone (the maximum therapeutic dose) …”
Section: Methodsmentioning
confidence: 99%
“…In addition, the free fraction is dose-dependent and exhibits circadian variability (approximately 22% higher in the morning) [74]. The PLN plasma unbound fraction demonstrates a high correlation with the salivary level and a lower correlation with the concentration of the prodrug prednisone (PN) [75,76]. Total and free concentrations of PLN+PN in the OF and plasma display an excellent association [76] (Table 2).…”
Section: Oral Fluids As a Matrix For Therapeutic Drug Monitoringmentioning
confidence: 99%
“…16 In brief, we obtained ultrafiltrate for the separation of unbound analytes using Centrifree YM-30 centrifugal filtration units (30,000 MW cutoff; Millipore Ireland BV, Country Cork, Ireland). 16 In brief, we obtained ultrafiltrate for the separation of unbound analytes using Centrifree YM-30 centrifugal filtration units (30,000 MW cutoff; Millipore Ireland BV, Country Cork, Ireland).…”
Section: Liquid Chromatography Tandem Mass Spectrometry Analysismentioning
confidence: 99%
“…In analogy to cortisol, the unbound or free fraction of PLN is biologically active; only unbound molecules can readily diffuse into target tissues and cells and are therefore considered clinically most relevant. 16 In the present study, the relationship between salivary and (free) serum predniso(lo)ne levels is further explored in a population of healthy volunteers after administration of a single oral dose of PLN. One way to overcome this problem might be the measurement of PLN levels in saliva, as concentrations in saliva may represent free PLN levels in blood.…”
Section: Introductionmentioning
confidence: 99%