Determination of Ultra-Low Level Plutonium Isotopes in Large Volume Environmental Water Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…It usually takes about 1 week to complete a measurement period, and sometimes even more than 10 days. At the same time, the alpha-energy values of 239 Pu (5.16, 5.14 MeV) and 240 Pu (5.17, 5.12 MeV) are very close, and this is a great challenge to the energy resolution (at least 25 keV) of the current ion-implanted passivated planar silicon detector [ 72 ], leading to the fact that only the total activity of 239+240 Pu can be measured. Beata Varga et al [ 73 ] used alpha spectroscopy to measure the activity of 239+240 Pu of grass samples in the hilly area of Budapest as 0.024 ± 0.01 Bq·kg −1 (fresh samples), with the MDA of 0.02 Bq·kg −1 .…”
Section: Measurement Methods Of 239 Pu 2...mentioning
confidence: 99%
“…It usually takes about 1 week to complete a measurement period, and sometimes even more than 10 days. At the same time, the alpha-energy values of 239 Pu (5.16, 5.14 MeV) and 240 Pu (5.17, 5.12 MeV) are very close, and this is a great challenge to the energy resolution (at least 25 keV) of the current ion-implanted passivated planar silicon detector [ 72 ], leading to the fact that only the total activity of 239+240 Pu can be measured. Beata Varga et al [ 73 ] used alpha spectroscopy to measure the activity of 239+240 Pu of grass samples in the hilly area of Budapest as 0.024 ± 0.01 Bq·kg −1 (fresh samples), with the MDA of 0.02 Bq·kg −1 .…”
Section: Measurement Methods Of 239 Pu 2...mentioning
confidence: 99%
“…In another work, plutonium, which is an important contaminant of emerging concern (CEC) for radioactive waste, was determined in environmental water samples by ICP-MS/MS. 51 Sample preparation included pre-concentration by co-precipitation with Ti(OH) 3 after Pu( iii ) oxidation by NaNO 2 , and matrix separation on a TEVA® resin column. The resulting matrix still contained Ti 3+ , and the use of 0.74 L min −1 and 0.37 L min −1 of nebulizer and dilution gas flow rates, respectively, was necessary to run these samples (Table 2).…”
Section: Application Of Aerosol Dilution To Challenging Sample Introd...mentioning
confidence: 99%