2022
DOI: 10.1002/xrs.3307
|View full text |Cite
|
Sign up to set email alerts
|

Determination of trace levels of uranium in waste solutions by energy dispersive X‐ray fluorescence following adsorption on graphene oxide

Abstract: This paper proposes a rapid X-ray fluorescence (XRF)-based screening method for the determination of trace uranium in solutions. In this method, uranium present in a solution was adsorbed onto graphene oxide (GO), which was collected and subjected to XRF analysis. Upon increasing the sodium ion concentration, the aggregation of GO was promoted, facilitating its collection. Since the GO-collecting membrane filter was significantly larger than the X-ray irradiation field of the XRF spectrometer, it was folded to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(12 citation statements)
references
References 27 publications
0
12
0
Order By: Relevance
“…A GO nanosheet (size ~600 nm, 4 mg mL −1 , dispersed in H 2 O, Merck & Co., Inc., Rahway, NJ, USA) was used to adsorb uranium. Similarly to our previous studies [ 17 , 22 , 23 , 24 ], the multielement standard XSTC-1407 (Spex CertiPrep Inc., Metuchen, NJ, USA), containing 10 μg mL −1 of each element (Co, Cs, Cu, Th, and U), was employed to adjust the uranium concentration in the standard sample. To obtain the fitting parameter for the Br Kβ peak, a 0.05 mol L −1 bromine solution (FUJIFILM Wako Pure Chemical Corporation, Osaka, Japan) was used.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…A GO nanosheet (size ~600 nm, 4 mg mL −1 , dispersed in H 2 O, Merck & Co., Inc., Rahway, NJ, USA) was used to adsorb uranium. Similarly to our previous studies [ 17 , 22 , 23 , 24 ], the multielement standard XSTC-1407 (Spex CertiPrep Inc., Metuchen, NJ, USA), containing 10 μg mL −1 of each element (Co, Cs, Cu, Th, and U), was employed to adjust the uranium concentration in the standard sample. To obtain the fitting parameter for the Br Kβ peak, a 0.05 mol L −1 bromine solution (FUJIFILM Wako Pure Chemical Corporation, Osaka, Japan) was used.…”
Section: Methodsmentioning
confidence: 99%
“…The preparation method employed herein was based on our previously reported study [ 17 ], and is summarized in Figure 2 . Initially, sodium perchlorate monohydrate was added to 75, 150, 225, and 300 mL of pure water until the salinity meter reading reached 3% ( n = 6).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations