1998
DOI: 10.1039/a708837j
|View full text |Cite
|
Sign up to set email alerts
|

Determination of trace elements in sea-water by inductively coupled plasma mass spectrometry after preconcentration by formation of water-soluble complexes and their adsorption onC18-bonded silica gel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

2000
2000
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 14 publications
0
11
0
Order By: Relevance
“…Since Olsen et al (1983) first integrated sample pretreatment on-line by combining an SPE column with an FI system, several environmental and biological applications have been reported with various sorbents-such as Chelex-100 (Nicolaï et al, 1999), silica-immobilized 8-hydroxyquinoline (I-8-HOQ; Hirata et al, 2003), C 18 -bonded silica gel (Akatsuka et al, 1998), and polymer sorbents (Bohrer et al, 1999)-for the simultaneous determination of trace and major elements in saline samples. Among the commercially available chelation-exchange substrates, iminodiacetate-based resins, such as Chelex-100, Muromac-A1, and Dowex A-1, have become the best-characterized in terms of their applications (Ebdon et al, 1991).…”
Section: In Vivo Monitoring Of the Transfer Kineticsmentioning
confidence: 99%
“…Since Olsen et al (1983) first integrated sample pretreatment on-line by combining an SPE column with an FI system, several environmental and biological applications have been reported with various sorbents-such as Chelex-100 (Nicolaï et al, 1999), silica-immobilized 8-hydroxyquinoline (I-8-HOQ; Hirata et al, 2003), C 18 -bonded silica gel (Akatsuka et al, 1998), and polymer sorbents (Bohrer et al, 1999)-for the simultaneous determination of trace and major elements in saline samples. Among the commercially available chelation-exchange substrates, iminodiacetate-based resins, such as Chelex-100, Muromac-A1, and Dowex A-1, have become the best-characterized in terms of their applications (Ebdon et al, 1991).…”
Section: In Vivo Monitoring Of the Transfer Kineticsmentioning
confidence: 99%
“…In fact, owing to the higher plasma robustness promoted by N 2 , addition of this molecular gas has found valuable application to complex samples analysis such as seawater, soil digests, slurries and other matrices. [7][8][9][10][11][12][13][14][15][16] In addition, Ar-N 2 -ICP proved its usefulness in reducing oxides and Ar polyatomic ions, which are interferents in ICP-MS. [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35] Researches dealing with the use of Ar-N 2 -ICP in axially viewed plasma in ICP OES have been quite limited. Ohata et al 36 demonstrated that plasma robustness (i.e., Mg(II)/Mg(I) ratio) was improved by using 1.3% of N 2 in the outer gas, whereas the robustness remained constant under higher amounts of N 2 .…”
Section: Introductionmentioning
confidence: 99%
“…Thus far, a number of spectroscopic techniques such as ame atomic absorption spectrometry (FAAS), [3][4][5][6] graphite furn ace ato m ic ab sorp tio n spectrosco py (GFAAS), 7,8 spectrophotometry, 9 -11 electrothermal (ET) atomization, 12,13 conductimetry, 14,15 inductively coupled plasmas optical emission spectroscopy (ICP-OES), 16,17 and inductively coupled plasma m ass spectroscopy (ICP-MS) [18][19][20] have been widely applied to the determination of Pb. Flow-injection (FI) analysis has been popularly combined with the above techniques.…”
Section: Introductionmentioning
confidence: 99%