2017
DOI: 10.1016/j.sab.2017.01.006
|View full text |Cite
|
Sign up to set email alerts
|

Determination of trace amount of cadmium using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(9 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…In the end, the total nitrogen in the solution was assessed by using flow analyzer-3 (BRAN+LUEBBE), and other macro-and micro-elements like potassium, magnesium, calcium, zinc, and phosphorus in the solution were assessed by using flame photometer FP6410. The remaining macro and microelements were analyzed by inductively coupled plasma mass spectroscopy (ICP-MS, Agilent, and 7700 X, USA) by the method of Firat [ 39 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the end, the total nitrogen in the solution was assessed by using flow analyzer-3 (BRAN+LUEBBE), and other macro-and micro-elements like potassium, magnesium, calcium, zinc, and phosphorus in the solution were assessed by using flame photometer FP6410. The remaining macro and microelements were analyzed by inductively coupled plasma mass spectroscopy (ICP-MS, Agilent, and 7700 X, USA) by the method of Firat [ 39 ].…”
Section: Methodsmentioning
confidence: 99%
“…The samples were ground into a powder with a grinder. After that, 0.2 g of oven-dried root and shoot samples were placed into microwave digestion tubes for further digestion by the method of Fırat et al [ 39 ]. The root and shoot samples were digested by adding nitric acid at the rate of 10 mL in each tube and covered the samples with a lid.…”
Section: Methodsmentioning
confidence: 99%
“…The N, K + , Cd, and Si contents in the plants were analyzed by inductively coupled plasma mass spectroscopy (ICP-MS, Agilent, and 7700 X, USA) after being oven-dried by following our previous study method (Fırat et al 2017) (see supplementary file heading 3).…”
Section: Determination Of Nutrient Elementsmentioning
confidence: 99%
“…At present, the trace amounts of cadmium is mainly analyzed by flame atomic absorption spectrometry (FAAS) [ 2 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 ], graphite furnace atomic absorption spectrometry (GFAAS) [ 19 , 20 , 21 , 22 , 23 ], inductively coupled plasma atomic emission spectrometry (ICP–OES) [ 24 ], and inductively coupled plasma mass spectrometry (ICP-MS) [ 25 , 26 , 27 , 28 ]. Compared with costly analysis technique, such as ICP-OES and ICPMS, FAAS is a conventional technique that has been widely applied in metals analysis because it is a less expensive and simpler alternative technique [ 29 , 30 ].…”
Section: Introductionmentioning
confidence: 99%
“…Dispersive liquid–liquid microextraction (DLLME) is an attractive method that has been used widely in the field of sample preparation since its innovation in 2006 [ 31 , 32 ]. The conventional and modified DLLME methods have been successfully applied to determine the trace amounts of cadmium in various matrices [ 15 , 16 , 17 , 18 , 19 , 22 , 23 , 24 , 25 , 26 , 27 ]. Generally, the pre-concentration of cadmium ions requires suitable complexing agents to form metal complexes and obtain high partition coefficients of cadmium between the aqueous phase and organic extraction solvents.…”
Section: Introductionmentioning
confidence: 99%