2009
DOI: 10.1039/b9ay00079h
|View full text |Cite
|
Sign up to set email alerts
|

Determination of total selenium by multicommutated-flow hydride generation atomic absorption spectrometry. Application to cow's milk and infant formulae

Abstract: A multicommutated flow system was designed and evaluated for the determination of selenium by hydride generation atomic absorption spectrometry (HG-AAS). It was applied to the determination of total selenium in samples of cow's milk (fluid and powder) and infant formulae. Linearity was satisfactory in the range up to 27.5 mg L À1 (h ¼ 0.082 C + 0.0033, h ¼ peak-height, absorbance, C ¼ concentration in mg L À1 , r 2 ¼ 0.999). Detection (3s) and quantification (10s) limits in solution were LD ¼ 0.08 mg L À1 and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0
3

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 23 publications
(21 reference statements)
0
13
0
3
Order By: Relevance
“…It was then cooled down to room temperature, 1 mL of 30% hydrogen peroxide was added, and the vial (loosely capped) was heated again for 2 minutes at 40% power. Afterwards, the contents of the vial were transferred quantitatively to a 50 mL Erlenmeyer flask containing 10 mL of 10% (w/v) sulfamic acid solution and 10 mL of concentrated HCl; the prereduction step was carried out by heating at gentle boiling on a hot plate for 1 hour and then cooled down to room temperature and diluted with water to 20.0 mL [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…It was then cooled down to room temperature, 1 mL of 30% hydrogen peroxide was added, and the vial (loosely capped) was heated again for 2 minutes at 40% power. Afterwards, the contents of the vial were transferred quantitatively to a 50 mL Erlenmeyer flask containing 10 mL of 10% (w/v) sulfamic acid solution and 10 mL of concentrated HCl; the prereduction step was carried out by heating at gentle boiling on a hot plate for 1 hour and then cooled down to room temperature and diluted with water to 20.0 mL [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…It has been already used by Ródenas-Torralba et al for the determination of tellurium in milk by hydride generation but coupled to atomic fluorescence detection [ 21 ]. In a previous work we developed and validated a multicommutated flow system for the determination of total selenium in milk and infant formulas [ 29 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The flow system was described elsewhere (Pistón et al 2009). It was based upon a Gilson (Villiers-le-Bel, France) Minipuls 2 multichannel peristaltic pump and two 3-way 12 V solenoid valves (NResearch, West Caldwell, NJ, USA, model 161T031) which were used for fluid control.…”
Section: Mcfa Systemmentioning
confidence: 99%
“…Since MCFA is a microanalytical technique, methods based on it usually present low reactive consumption and generate low volumes of chemical residues. The literature reflects the usefulness of this technique that has been applied to the determination of different analytes in a wide range of matrixes (Knochen et al 2005;Pistón et al 2006;Sixto and Knochen 2009;Pistón et al 2009). …”
Section: Introductionmentioning
confidence: 97%