1982
DOI: 10.1007/bf00377828
|View full text |Cite
|
Sign up to set email alerts
|

Determination of total pentachlorophenol in the urine of workers

Abstract: Free pentachlorophenol (PCP) represents a small and variable fraction of total PCP excreted in the urine of exposed workers. A method incorporating hydrolysis is essential to be able to relate PCP excretion to absorbed dose. 3,5-Dichloro-2,4,6-tribromophenol (DTP) is added as an internal standard to a urine sample which is then acidified and steam-distilled. The distillate is made alkaline and extracted with methylene chloride to remove interferences. The distillate is then acidified and the phenols extracted … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1988
1988
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…These methods typically employ some deconjugation step, a solvent or solid phase extraction, and analysis using GC-ECD, GC-MS or GC-MS/MS. 62,64,122,[175][176][177] Many of these methods measure PCP in conjunction with other chlorinated phenols. The LODs of these methods are in the low or sub mg/L range.…”
Section: Fungicidesmentioning
confidence: 99%
“…These methods typically employ some deconjugation step, a solvent or solid phase extraction, and analysis using GC-ECD, GC-MS or GC-MS/MS. 62,64,122,[175][176][177] Many of these methods measure PCP in conjunction with other chlorinated phenols. The LODs of these methods are in the low or sub mg/L range.…”
Section: Fungicidesmentioning
confidence: 99%
“…Grab samples were collected on Thursda ys to reflect exposure over the previou s several weeks with some influence due to recent daily fluctuations, since estimates of the excretion halftimes of tetra-and pentachlorophenate vary from severa l da ys to about two months (14). All the samples were collected in silanized amber jars (15).…”
Section: Measurement Of Chlorophenate Expo Surementioning
confidence: 99%
“…All samples were collected in silanized wide-mouth amber glass jars to minimize the effects of photo-decomposition and adsorption to the sides of the container [Drummond et al, 19821. Extractions and analyses were based on methods developed for total penta-and tetrachlorophenates [Drummond et al, 1982; Workers' Compensation Board of B.C., 19841, using acid hydrolysis, extraction with toluene, and quantification using a Varian 6000 gas chromatograph with an electron capture detector. Specific gravity was also measured to indicate if any samples were unusu- ally dilute or concentrated.…”
Section: Phase 2: Urine Samplingmentioning
confidence: 99%