2008
DOI: 10.1016/j.ijheatmasstransfer.2007.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Determination of thermal contact resistance from transient temperature measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
47
0
3

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 122 publications
(52 citation statements)
references
References 9 publications
2
47
0
3
Order By: Relevance
“…This corresponds quite well with our experiments, and also with Fieberg 3 , but in our case, directly after the contact, it takes some time (around 0.3-0.5 s) to stabilize the level of thermal contact conductance. This is caused by vibrations after the sudden contact of the temperature sensor and the heated test plate.…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…This corresponds quite well with our experiments, and also with Fieberg 3 , but in our case, directly after the contact, it takes some time (around 0.3-0.5 s) to stabilize the level of thermal contact conductance. This is caused by vibrations after the sudden contact of the temperature sensor and the heated test plate.…”
Section: Resultssupporting
confidence: 93%
“…3 The two bodies are in contact and their ends are cooled and heated. The temperature distribution is measured using thermocouples inside the bodies.…”
Section: Methods Of Measurementmentioning
confidence: 99%
“…Fieberg et Kneer [Fieberg et Kneer, 2008] ont réalisé une étude sur l'estimation de la conductance de .contact dans le temps en fonction de la pression exercée sur le contact. Cette étude avait pour but de quantifier l'impact de la pression sur le contact pour l'appli quer au cas des moteurs où l'on a souvent une grande pression, environ 250 MPa.…”
Section: Bibliographieunclassified
“…-la conductance thermique de contact n'étant pas uniforme sur la surface, il ne sera pas possible de se baser sur les études suivantes : [Atchonouglo et al, 2008] [Shojaeefard et al, 2009] [Fieberg et Kneer, 2008]. …”
Section: Bibliographieunclassified
“…In general, the measurement methods of TCR can be divided into steady state method [1] and transient state method [2]. In the study of Bi et al [3], the stainless steel, copper, and AIN (Aluminum Nitride) are used as specimen and LPM (laser photothermal method) which is one of the transient methods was employed to measure the TCR.…”
Section: Introductionmentioning
confidence: 99%