2016
DOI: 10.1007/s11018-016-1077-z
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the True Temperature During Selective Laser Melting of Metal Powders Based on Measurements with an Infrared Camera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Using numerical modeling and experiments, Du et al 71 show that LPBF of AlSi10Mg at VED=106 J/mm 3 could result in melt pool temperatures higher than 3086 K, which is higher than the evaporation temperatures of Fe, Cr and Ni. A separate study by Doubenskaia et al 72 employed an IR camera to investigate the melt pool temperature profiles during LPBF of 316 L SS (P=30 W, v s = 50 mm/s), the results indicated that the melt pool peak temperatures reached 2500 K. A few other works by Ansari et al 73 , and Mirkoohi et al 74 . all point towards the fact that melt pool temperatures would go higher than the vaporization temperature of Fe, Cr and Ni, with the volumetric energy density (VED= 133-1333 J/mm 3 ) used www.nature.com/scientificreports www.nature.com/scientificreports/ in this work.…”
Section: Clad-heat Affected Zone Profile Properties As Presented Inmentioning
confidence: 98%
“…Using numerical modeling and experiments, Du et al 71 show that LPBF of AlSi10Mg at VED=106 J/mm 3 could result in melt pool temperatures higher than 3086 K, which is higher than the evaporation temperatures of Fe, Cr and Ni. A separate study by Doubenskaia et al 72 employed an IR camera to investigate the melt pool temperature profiles during LPBF of 316 L SS (P=30 W, v s = 50 mm/s), the results indicated that the melt pool peak temperatures reached 2500 K. A few other works by Ansari et al 73 , and Mirkoohi et al 74 . all point towards the fact that melt pool temperatures would go higher than the vaporization temperature of Fe, Cr and Ni, with the volumetric energy density (VED= 133-1333 J/mm 3 ) used www.nature.com/scientificreports www.nature.com/scientificreports/ in this work.…”
Section: Clad-heat Affected Zone Profile Properties As Presented Inmentioning
confidence: 98%
“…220 μmsolidification distance/100 μm beam diameter reported in simulations conducted in [7]). The typical SLM temperature distribution of an elongated-tail shape suggests a much lower s/d ratio in directions perpendicular to the scanning vector [8].…”
Section: Temperature Gradients and Cooling Rate In Selective Laser Mementioning
confidence: 98%
“…A number of excellent optimal monitoring systems has been developed, in particular those by Craeghs et al [98][99][100][101], Kleszczynski et al [119], Clijsters et al [120], Chivel [121], Grasso et al [122], Hirsh et al [123], Kanko et al [124] and Lott et al [125]. Infrared thermography systems for SLM/DMSL have been developed by Rodriguez et al [126] and Smurov et al [127].…”
Section: Optical Process Monitoringmentioning
confidence: 99%