Determination of the S(+)- and R(−)-enantiomers of baclofen in plasma and urine by gas chromatography using a chiral fused-silica capillary column and an electron-capture detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0

Year Published

1992
1992
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(16 citation statements)
references
References 11 publications
0
16
0
Order By: Relevance
“…Many efforts have been devoted to the development of analytical methods for the determination of BAL using spectrophotometry [3,4], potentiometry [5], thin-layer chromatography [6], gas chromatography [7], high-performance liquid chromatography (HPLC) [8,9,10] and capillary electrophoresis [11,12]. As the target analyte is usually present in complex samples at low concentrations, HPLC coupled with all kinds of detection methods such as UV-vis absorption [8,9], fluorescence detection [10] and mass spectrometry (MS) [13] is an especially effective and important technique due to its separation process and high selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…Many efforts have been devoted to the development of analytical methods for the determination of BAL using spectrophotometry [3,4], potentiometry [5], thin-layer chromatography [6], gas chromatography [7], high-performance liquid chromatography (HPLC) [8,9,10] and capillary electrophoresis [11,12]. As the target analyte is usually present in complex samples at low concentrations, HPLC coupled with all kinds of detection methods such as UV-vis absorption [8,9], fluorescence detection [10] and mass spectrometry (MS) [13] is an especially effective and important technique due to its separation process and high selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…All these methods were only used for the determination of baclofen racemate. For chiral analysis, different methods were developed such as GC with electron capture detection [26,27] as well as HPLC coupled with fluorescence [28,29], UV [30,31], and MS detection [32]. As reported in the literature, there are only few papers dedicated to the chiral separation of baclofen by CE with derivatized CDs [33] and crown ethers [34,35] in acidic media with UV detection.…”
Section: Introductionmentioning
confidence: 99%
“…So far few analytical methods have been developed to determine each baclofen enantiomer in biologic material [8][9][10][11]. Those methods that do exist require troublesome extraction and derivatization procedures for sample cleanup, enantioselective separation, or sensitive fluorescence detection.…”
Section: Introductionmentioning
confidence: 99%