2013
DOI: 10.1016/j.nima.2013.02.006
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the plutonium content in a spent fuel assembly by passive and active interrogation using a differential die-away instrument

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(24 citation statements)
references
References 1 publication
1
23
0
Order By: Relevance
“…indicated in Figure 5-12 should be considered with limitations, however the trend seems to be rather smooth raising the possibility of a straight forward calibration with more data. Comparing these trends to results in [33] it is worth noting that the results in this work trend consistently in a linear fashion while the previous results do not, as shown in Figure 5-12. However, the CT of 1 y that breaks the linear trend in the DDA results was not investigated in this work, therefore based on the range of CT investigated in both papers, it can still be concluded that the CT dependence of the fitting parameters of eq.…”
Section: Ddsi Methodologysupporting
confidence: 62%
See 4 more Smart Citations
“…indicated in Figure 5-12 should be considered with limitations, however the trend seems to be rather smooth raising the possibility of a straight forward calibration with more data. Comparing these trends to results in [33] it is worth noting that the results in this work trend consistently in a linear fashion while the previous results do not, as shown in Figure 5-12. However, the CT of 1 y that breaks the linear trend in the DDA results was not investigated in this work, therefore based on the range of CT investigated in both papers, it can still be concluded that the CT dependence of the fitting parameters of eq.…”
Section: Ddsi Methodologysupporting
confidence: 62%
“…However the review was held in the rather early stages of the investigation of these techniques and their capabilities have since been proven that were not believed to be possible during the review. For example, it was assumed that DDA and DDSI could not determine total elemental plutonium content, but that his since proven to be incorrect [33,34]. and SINRD which were expected to be less expensive.…”
Section: Comparison Of Ddsi Methods With Other Nda Techniquesmentioning
confidence: 99%
See 3 more Smart Citations