Determination of tetrodotoxin in puffer-fish by liquid chromatography-electrospray ionization mass spectrometry

Abstract: A simple and reliable method using liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) for the determination of tetrodotoxin in the puffer-fish has been developed. The LC separation was performed on a Shodex RSpak NN-414 column (15 cm x 4.6 mm id) using 20 mM ammonium acetate-methanol (75 + 25) as the mobile phase at a flow rate of 0.5 ml min(-1). The positive ionization produced the typical [M + H]+ molecular ion of tetrodotoxin (m/z 320). The calibration graph for tetrodotoxin was rec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 6 publications
0
22
0
Order By: Relevance
“…The lengthy evaporation steps as practiced by others [6,25,29] was omitted. In several studies, the recovered supernatant was subjected to defatting procedure using dichloromethane [6,11,25], chloroform [29,30] or diethyl ether [28] followed by further cleanup procedures before the sample could be analyzed by analytical instruments. For over 30 years, SPE and preparative column have been used to extract TTX.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The lengthy evaporation steps as practiced by others [6,25,29] was omitted. In several studies, the recovered supernatant was subjected to defatting procedure using dichloromethane [6,11,25], chloroform [29,30] or diethyl ether [28] followed by further cleanup procedures before the sample could be analyzed by analytical instruments. For over 30 years, SPE and preparative column have been used to extract TTX.…”
Section: Resultsmentioning
confidence: 99%
“…Mass spectrometry (MS) coupled with LC or GC is a sensitive technique for identification of TTX. However, due to the complexity of sample matrices and insolubility of TTX in organic solvent, the LC-MS [8,9,11,15,18,[24][25][26][27] or LC-MS/MS [4,6,13,15,18,27] is a preferred method than GC-MS. The drawback for LC-MS and LC-MS/MS analysis is that it involves the use of expensive instruments that require higher maintenance compared to GC-MS.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, liquid chromatography-mass spectrometry (LC-MS) has been recognized as a useful method to analyze TTX [8][9][10][11][12][13][14][15][16]. We previously reported two different systems to separate TTX analogs by LC-MS analysis.…”
Section: Introductionmentioning
confidence: 99%