1996
DOI: 10.1007/bf02060314
|View full text |Cite
|
Sign up to set email alerts
|

Determination of technetium-99 in aqueous samples by isotope dilution inductively coupled plasma-mass spectrometry

Abstract: Prepared for lhc L.'. 5. Departrt, er_t.of Energy w,der contract No. DE.-.AC()9--89SR1803.5 _ASTER _._ DISTT_BU'_O_O_ rt.4fSD,OCUME!NT tSUNLIMI"I_£'D DISCLAIMER This report was prepared as an account of work sponsored by an agency of fl_eUnited States Government.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

1996
1996
2016
2016

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(9 citation statements)
references
References 9 publications
(5 reference statements)
0
9
0
Order By: Relevance
“…1 that the only differences between the methods A1 and A2 are the different chromatographic columns used to concentrate technetium and isolate the analyte from Ru and Mo. For Ru decontamination, the use of the TEVA·Spec resins (Eichrom Industries, Inc.) has been proposed [1]. The DF for Ru and Mo are high [21] and since the eluant volumes involved are very low, its use is clearly advantageous when compared to conventional exchange resins.…”
Section: Methods A2mentioning
confidence: 98%
See 2 more Smart Citations
“…1 that the only differences between the methods A1 and A2 are the different chromatographic columns used to concentrate technetium and isolate the analyte from Ru and Mo. For Ru decontamination, the use of the TEVA·Spec resins (Eichrom Industries, Inc.) has been proposed [1]. The DF for Ru and Mo are high [21] and since the eluant volumes involved are very low, its use is clearly advantageous when compared to conventional exchange resins.…”
Section: Methods A2mentioning
confidence: 98%
“…The DF for Ru and Mo are high [21] and since the eluant volumes involved are very low, its use is clearly advantageous when compared to conventional exchange resins. The conditions for loading, cleaning and the Tc elution for this microcolumn have been well described elsewhere [1,10,21], thus our efforts are to investigate the column performance when high volume solutions are loaded. Or, when the same microcolumn is reused multiple times using modest sample volumes.…”
Section: Methods A2mentioning
confidence: 99%
See 1 more Smart Citation
“…Both of these are commercially available. 3M prepared a membrane containing the EIChroM Industries, Inc. (Darien IL) TEVA resin, which has been well characterized for the extraction of technetium &om aqueous solution (Beals, 1996). These are called the TEVA disks in the following discussions.…”
Section: Memporetmmentioning
confidence: 99%
“…At the SRS samples are then anal* by isotope dilutiodmductively coupled plasma-mass spectrometry @D/ICP-MS; Beals, 1996) to achieve the required detection limit of 1 pCiL (0.06 nanogram per liter). One nanogram (1.4 pCi) of Tc-97 is added to the aqueous sample as a tracer, the technetium is extracted fiom the aqueous sample by passing through an extraction chromatography column.…”
Section: Introductionmentioning
confidence: 99%