1995
DOI: 10.1021/ie00043a036
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Specific Cake Resistance with a New Capillary Suction Time Apparatus

Abstract: DOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer review.• The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

1998
1998
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(29 citation statements)
references
References 3 publications
0
29
0
Order By: Relevance
“…5 A rectangular instead of a circular funnel allows for an easy mathematical treatment of CST data. Therefore, a further set of experiments was performed with a rectangular funnel (not supplied as part of the standard kit) of 18 × 18 × 20 mm 3 (width, length and height, respectively) replacing the circular funnel. The rectangular funnel volume of 6.48 cm 3 was similar to the 18 mm circular funnel.…”
Section: Materials and Methodology Cst Devices And Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…5 A rectangular instead of a circular funnel allows for an easy mathematical treatment of CST data. Therefore, a further set of experiments was performed with a rectangular funnel (not supplied as part of the standard kit) of 18 × 18 × 20 mm 3 (width, length and height, respectively) replacing the circular funnel. The rectangular funnel volume of 6.48 cm 3 was similar to the 18 mm circular funnel.…”
Section: Materials and Methodology Cst Devices And Measurementsmentioning
confidence: 99%
“…Therefore, a further set of experiments was performed with a rectangular funnel (not supplied as part of the standard kit) of 18 × 18 × 20 mm 3 (width, length and height, respectively) replacing the circular funnel. The rectangular funnel volume of 6.48 cm 3 was similar to the 18 mm circular funnel. A rectangular funnel should principally be applicable for 'light' and 'heavy' sludges.…”
Section: Materials and Methodology Cst Devices And Measurementsmentioning
confidence: 99%
“…Lee and Hsu (1994) proposed a method that allowed SRF to be calculated without the liquid invasion volume measurement using capillary suction apparatus. A similar work by Herwijn et al (1995) presented a newly developed model of CST apparatus able to determine specific cake resistances of both unflocculated and flocculated sludges. Sawalha and Scholz (2010) provided a mathematical model which related CST, SRF and other parameters, such as temperature and solids content.…”
Section: Relationship Between Cst and Srfmentioning
confidence: 99%
“…It has been found that lower CST values are obtained among the sludge with lower solid content (Sarikaya and Al-Marshoud, 1993;Herwijn et al, 1995). There is a certain limit in the interpretation of CST since the CST is not an intensive property.…”
Section: Capillary Suction Time (Cst)mentioning
confidence: 99%