1974
DOI: 10.1007/bf00431330
|View full text |Cite
|
Sign up to set email alerts
|

Determination of sodium and potassium in salt by atomic absorption spectrophotometry or potassium by gravimetry with tetraphenyl boron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Usually, Na + and K + quantification is held directly by flame atomic absorption spectroscopy after the sample has been dissolved in distilled water and filtered or by atomic emission spectroscopy, widely used in IA cation group determinations . An alternative is the use of X-ray fluorescence (XRF), using the measured intensity and energy characteristics of X-rays emitted by a sample when irradiated with high-energy electromagnetic radiation. , Energy dispersive X-ray fluorescence (EDXRF) is a fast, low operating cost, nondestructive, and truly multielement analytical technique, providing both qualitative and quantitative results .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Usually, Na + and K + quantification is held directly by flame atomic absorption spectroscopy after the sample has been dissolved in distilled water and filtered or by atomic emission spectroscopy, widely used in IA cation group determinations . An alternative is the use of X-ray fluorescence (XRF), using the measured intensity and energy characteristics of X-rays emitted by a sample when irradiated with high-energy electromagnetic radiation. , Energy dispersive X-ray fluorescence (EDXRF) is a fast, low operating cost, nondestructive, and truly multielement analytical technique, providing both qualitative and quantitative results .…”
Section: Introductionmentioning
confidence: 99%
“…17, 18 Studies have shown that lowering blood pressure can be achieved by adopting a diet that replaces common salt by low-sodium salt. 19−21 Usually, Na + and K + quantification is held directly by flame atomic absorption spectroscopy after the sample has been dissolved in distilled water and filtered 22 or by atomic emission spectroscopy, widely used in IA cation group determinations. 23 An alternative is the use of X-ray fluorescence (XRF), using the measured intensity and energy characteristics of X-rays emitted by a sample when irradiated with high-energy electromagnetic radiation.…”
Section: ■ Introductionmentioning
confidence: 99%