2020
DOI: 10.1002/jrs.5871
|View full text |Cite
|
Sign up to set email alerts
|

Determination of skin penetration profiles by confocal Raman microspectroscopy: Evaluation of interindividual variability and interlab comparability

Abstract: Confocal Raman microspectroscopy is being increasingly used to investigate the skin penetration of actives and excipients. The aim of the present study was to compare results obtained with skin from different donors, acquired with two Raman systems: the RiverD gen2 Skin Composition Analyzer and the WiTec alpha 500 instrument. To elucidate the interindividual variability between the skin donors and to find out whether the two systems would give similar results in skin penetration analysis, we compared the penet… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 21 publications
(87 reference statements)
1
8
0
Order By: Relevance
“…However, procaine signals deeper in the skin of nearly 8–9 µm can still be found with the effect of adding L23 in formulations. This is in line with our previous studies [ 6 , 32 ]. Higher procaine signals were observed at the upper layer of the skin (within 4 µm).…”
Section: Resultssupporting
confidence: 94%
See 1 more Smart Citation
“…However, procaine signals deeper in the skin of nearly 8–9 µm can still be found with the effect of adding L23 in formulations. This is in line with our previous studies [ 6 , 32 ]. Higher procaine signals were observed at the upper layer of the skin (within 4 µm).…”
Section: Resultssupporting
confidence: 94%
“…As the skin samples from one donor allow for a limited number of measurements, two different donors were used in respective in-line and off-line studies, which may also lead to differences. Different donors may respond differently to the penetration enhancer [ 32 ].…”
Section: Resultsmentioning
confidence: 99%
“…Different algorithms in analysis of Raman spectra are proposed by many scientific groups worldwide to determine the penetration depth of topically applied formulations into the skin [70,[86][87][88][89][90][91][92][93][94][95][96]. These algorithms can be efficiently used to determine penetration profiles into the SC in vivo and ex vivo.…”
Section: Secondary and Tertiary Structure Of Keratinmentioning
confidence: 99%
“…Recently, penetration studies performed in parallel with a common multi-purpose confocal Raman spectroscope by WiTec (alpha 500) and the River Diagnostics device (gen2 SCA) were found to deliver comparable outcomes. 127 Binder et al obtained similar enhancement ratios for procaine HCl when using polyoxyethylene23-lauryl ether to promote skin penetration. This is promising considering that instruments of two different suppliers were used in different laboratories, working with different objectives, pinholes and laser wavelengths.…”
Section: Skin Penetration Studiesmentioning
confidence: 84%