2017
DOI: 10.1515/cclm-2017-0175
|View full text |Cite
|
Sign up to set email alerts
|

Determination of serum calcium levels by42Ca isotope dilution inductively coupled plasma mass spectrometry

Abstract: ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…Such loss will result in crucial errors in protein quantification. Due to the low ionization efficiency of heteroatoms (such as phosphorus and sulfur which are covalently bonded to the protein's primary structure) and its susceptibility to severe spectral line interference, 24,25 it is difficult to measure the heteroatoms by ICP-MS directly, and the measurement of heteroatoms is also interfered by polyatomic ions. 26,27 In fact, the use of the collision reaction cells and high-resolution ICP-MS instrumentation to remove polyatomic interferences may hinder the applicability of ICP-MS quantification in biological applications, usually requiring low limits of detection (LOD).…”
Section: Absolute Quantification Of Metalloproteins By Using Icp-ms Naturally Present Elements (P S Se and Metals)mentioning
confidence: 99%
“…Such loss will result in crucial errors in protein quantification. Due to the low ionization efficiency of heteroatoms (such as phosphorus and sulfur which are covalently bonded to the protein's primary structure) and its susceptibility to severe spectral line interference, 24,25 it is difficult to measure the heteroatoms by ICP-MS directly, and the measurement of heteroatoms is also interfered by polyatomic ions. 26,27 In fact, the use of the collision reaction cells and high-resolution ICP-MS instrumentation to remove polyatomic interferences may hinder the applicability of ICP-MS quantification in biological applications, usually requiring low limits of detection (LOD).…”
Section: Absolute Quantification Of Metalloproteins By Using Icp-ms Naturally Present Elements (P S Se and Metals)mentioning
confidence: 99%
“…The method was established by the National Center of Clinical Laboratory and was described in the previous paper. [ 9 ] All of the samples (48 patient samples and 25 processed materials) were divided into 12 subsets and detected over a period of 12 days.…”
Section: Ethodsmentioning
confidence: 99%