2008
DOI: 10.1152/ajprenal.00588.2007
|View full text |Cite
|
Sign up to set email alerts
|

Determination of plasma and urinary angiotensinogen levels in rodents by newly developed ELISA

Abstract: We recently reported that urinary excretion rates of angiotensinogen provide a specific index of the intrarenal renin-angiotensin system status in angiotensin II-dependent hypertensive rats. Angiotensinogen concentrations in mouse plasma are thought to be much lower than those in rat plasma; however, detailed information is deficient due to lack of direct quantitative measurements of rodent angiotensinogen. To elucidate this issue, we have developed a quantitative method for measurement of rodent angiotensinog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
60
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 59 publications
(64 citation statements)
references
References 30 publications
3
60
1
Order By: Relevance
“…Plasma AGT levels and 24-h urinary AGT excretion were measured by a specific AGT ELISA as previously described (18,20). Briefly, highly purified recombinant rodent AGT protein was used as the standard.…”
Section: Animalsmentioning
confidence: 99%
“…Plasma AGT levels and 24-h urinary AGT excretion were measured by a specific AGT ELISA as previously described (18,20). Briefly, highly purified recombinant rodent AGT protein was used as the standard.…”
Section: Animalsmentioning
confidence: 99%
“…10,37,38 Urinary albumin was measured by ELISA (Nephrat II; Exocell, Philadelphia, PA). Plasma samples or the whole-kidney tissue were homogenized in a buffer containing 20 mM TriszHCl, 1 mM EGTA, pH 7.0, and a protease inhibitor cocktail (BD Bioscience, San Jose, CA); 40 mg protein was separated on a 4%-20% SDS-PAGE and transferred onto polyvinylidene difluoride membrane.…”
Section: Plasma Kidney and Urinary Protein Content Measurementmentioning
confidence: 99%
“…21,22 After decapitating the rats, tissues of interest were carefully resected and boiled for 10 min in 10 volumes of distilled H 2 O. Acetic acid was then added to the samples to a final concentration of 1.0 mol l ƀ1 , and the samples were homogenized using a Polytron mixer and then centrifuged for 20 min (12 000 r.p.m. at 4 1C).…”
Section: Sample Preparation For Radioimmunoassay (Ria)mentioning
confidence: 99%
“…The angiotensinogen concentrations in plasma were determined using an ELISA purchased from Immuno-Biological Laboratories (Gunma, Japan). 21,22 Plasma renin activity was determined using a GammaCoat Plasma Renin Activity kit from Kyowa Medex (Tokyo, Japan). Estimates of renin activity were based on the plasma concentrations of generated Ang I following incubation at 37 1C.…”
Section: Measurement Of Proang-12 and Other Components Of The Rasmentioning
confidence: 99%