1977
DOI: 10.1515/cclm.1977.15.1-12.353
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Phenobarbital and Phenytoin in Serum by a Mechanized Enzyme Immunoassay (EMIT) in Comparison with a Gas-Liquid Chromatographie Method

Abstract: The antiepileptic drugs phenobarbital and phenytoin were determined in serum by enzyme immunoassay (Emit, Syva Corp.) and gas-liquid chromatography. The Emit assays were mechanized by the use of an Eppendorf analyzer 5010. The precision of the Emit system was sufficient (coefficient of variation within series 6-13% and from day to day 8-15% with various calibrators and control sera). Moreover the Emit method is rapid, specific and easy to perform. The procedure requires only 10 of serum per determination. A di… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1978
1978
1984
1984

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 12 publications
(4 reference statements)
0
7
0
Order By: Relevance
“…in routine laboratories (1)(2)(3)(4)(5)(6). 2 ) Abbreviations: EMIT R = Enzyme multiplied immunoassay technique, ELISA = Enzyme linked immunosorbent assay, Enzyme immunoassays 2 ) for the determination of ENZYMUN R = trade name for various enzyme immunoassays thyrosine ^d thyroxine binding inde* (TBI).based ^^^iS^'^SSSSSSKS…”
Section: Introductionmentioning
confidence: 99%
“…in routine laboratories (1)(2)(3)(4)(5)(6). 2 ) Abbreviations: EMIT R = Enzyme multiplied immunoassay technique, ELISA = Enzyme linked immunosorbent assay, Enzyme immunoassays 2 ) for the determination of ENZYMUN R = trade name for various enzyme immunoassays thyrosine ^d thyroxine binding inde* (TBI).based ^^^iS^'^SSSSSSKS…”
Section: Introductionmentioning
confidence: 99%
“…The determinations were performed as previously described (5) using an Eppendorf analyzer 5010 (Eppendorf, D-2000 Hamburg). The results were calculated by on-line data processing using an empirical spline interpolation (13).…”
Section: Methodsmentioning
confidence: 99%
“…In order to improve practicability we used the newly available stationary phase SP 2510 DA (1,2) that allows the simultaneous determination of antiepileptic drugs without derivatisation under isothermal conditions -important prerequisites for a mechanization of gas chromatography. As EMIT analyses are in widespread use we were interested in the comparison of results obtained by these two procedures, to see if they are interchangeable (3)(4)(5)(6)(7)(8)(9)(10). Identical values would mean that the methods could be selected according to practical necessities, different values that at least one method is less reliable.…”
Section: Introductionmentioning
confidence: 99%
“…In vitro solution + (5 I'g/ml) Oellerich et al (1977) S-RIA 5Ol'g/ml + (1.37 I'g/ml)a Stanley and Peikert (1978) ::9…”
Section: '9/mlmentioning
confidence: 99%