2000
DOI: 10.1007/s11746-000-0023-7
|View full text |Cite
|
Sign up to set email alerts
|

Determination of peroxide value by fourier transform near‐infrared spectroscopy

Abstract: A Fourier transform‐near infrared (FT‐NIR) method originally designed to determine the peroxide value (PV) of triacylglycerols at levels of 10–100 PV was improved upon to allow for the analysis of PV between 0 and 10 PV, a range of interest to the edible oil industry. The FT‐NIR method uses convenient disposable glass vials for sample handling, and PV is determined by spectroscopically measuring the conversion of triphenylphosphine (TPP) to triphenylphosphine oxide (TPPO) when reacted with hydroperoxides. A pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
29
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(29 citation statements)
references
References 5 publications
0
29
0
Order By: Relevance
“…To date, FT-NIR methods have been reported for the determination of IV, 117,118 trans content, 117,119 cis content, 117 SN, 117 and PV. 34,120 These methods are analogous to the MIR methods described in Section 2.1.2 but offer the advantage of greater ease of sample handling. For example, for the determination of IV 118 and trans content, 119 good analytical accuracy and precision were obtained by analyzing fats and oils in disposable glass vials placed in a thermostated holding block.…”
Section: Fatmentioning
confidence: 99%
“…To date, FT-NIR methods have been reported for the determination of IV, 117,118 trans content, 117,119 cis content, 117 SN, 117 and PV. 34,120 These methods are analogous to the MIR methods described in Section 2.1.2 but offer the advantage of greater ease of sample handling. For example, for the determination of IV 118 and trans content, 119 good analytical accuracy and precision were obtained by analyzing fats and oils in disposable glass vials placed in a thermostated holding block.…”
Section: Fatmentioning
confidence: 99%
“…[7][8][9] The McGill IR Group has already developed various spectroscopic methods using Fourier Transform Infrared (FTIR) in combination with chemometrics techniques as alternatives to the official titrimetric methods in the quantitative determination of important quality parameters of oils and fats such as saponification number, [10] iodine value, [10][11][12][13] cis and trans content, [10,13] peroxide value, [14][15][16] and moisture. [17] For the determination of FFAs in EVOOs using spectroscopic methods, a number of articles have been published.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, spectroscopic Fourier transformed infrared (FTIR) coupled with chemometric methods have been successfully used to detect olive oil adulteration [16][17][18] and freshness [19]. The chemometric algorithm partial least squares (PLS) has been repeatedly and extensively used to obtain different quality parameters of edible oils [20][21][22][23][24][25]. In particular, FTIR-PLS has been recently applied to the evaluation of the fatty acid composition and other quality parameters of VOO [26] and also to predict the total antioxidant capacity of the red wine samples [27].…”
Section: Introductionmentioning
confidence: 99%