1999
DOI: 10.1016/s0378-4347(98)00560-x
|View full text |Cite
|
Sign up to set email alerts
|

Determination of paroxetine in plasma by high-performance liquid chromatography for bioequivalence studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2001
2001
2014
2014

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(14 citation statements)
references
References 9 publications
0
14
0
Order By: Relevance
“…195 Paroxetine is derivatized with pentafluorobenzyl carbamate or heptafluorobutyric anhydride before injection onto a GC-MS in negative chemical ionization mode or on a GC-ECD configuration. 298−300 In LC, the following detectors are used: UV, 147,228,229,301,302 DAD, 146 fluorescence, 50,57,147,232,303,304 coulometric detection, 305 and mass detectors in electrospray 152,306,307 as well as in APCI mode. 153 When using the UV detector, a typical spectrum arises in acidic conditions at absorption of 233, 264, 270 and 293 nm.…”
Section: Methodsmentioning
confidence: 99%
“…195 Paroxetine is derivatized with pentafluorobenzyl carbamate or heptafluorobutyric anhydride before injection onto a GC-MS in negative chemical ionization mode or on a GC-ECD configuration. 298−300 In LC, the following detectors are used: UV, 147,228,229,301,302 DAD, 146 fluorescence, 50,57,147,232,303,304 coulometric detection, 305 and mass detectors in electrospray 152,306,307 as well as in APCI mode. 153 When using the UV detector, a typical spectrum arises in acidic conditions at absorption of 233, 264, 270 and 293 nm.…”
Section: Methodsmentioning
confidence: 99%
“…Some analytical methods, such as HPLC, [2][3][4][5][6][7][8][9][10][11][12] HPLC-GC, 13 GC, 14 GC-MS 15 and capillary liquid chromatography 16 have been reported for PRX in biological fluids and pharmaceutical dosage forms.…”
Section: Introductionmentioning
confidence: 99%
“…gas chromatography (GC) with electro-capture detection (Lai et al, 2000), nitrogen-phosphorus detection (Lacassie et al, 2000) or negative ion chemical ionization mass spectrometry (Leis et al, 2001(Leis et al, , 2002 and liquid chromatography (LC) with ultraviolet (UV) detection (Foglia et al, 1997;Bagli et al, 1997;Molander et al, 2002;Kristoffersen et al, 1999), and fluorescence detection (Lacassie et al, 2000;Kristoffersen et al, 2000;Lopez-Calull and Dominguez, 1999;Shin et al, 1998) have appeared in literature to analyze paroxetine in biological fluids. Methods published prior to 1996 have been summarized in a review article (Eap and Baumann, 1996).…”
mentioning