2006
DOI: 10.1134/s1061934806100029
|View full text |Cite
|
Sign up to set email alerts
|

Determination of organic compounds in human hair

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 131 publications
0
3
0
Order By: Relevance
“…If, however, the third quadrupole is set up to work in SIM mode with low mass resolution and uniformly transfer all of the masses of the product ion, a scan of the first quadrupole around the molecular ion group of isotopomers will generate the true, nascent isotope abundance of the molecular ions. As is known [2][3][4][5][6][7][8][9][10][11][12][13] such isotope abundance can be used to derive possible elemental formulae with declining order of matching to the experimental data.…”
Section: The Isotope Abundance Analysis Ms/ms Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…If, however, the third quadrupole is set up to work in SIM mode with low mass resolution and uniformly transfer all of the masses of the product ion, a scan of the first quadrupole around the molecular ion group of isotopomers will generate the true, nascent isotope abundance of the molecular ions. As is known [2][3][4][5][6][7][8][9][10][11][12][13] such isotope abundance can be used to derive possible elemental formulae with declining order of matching to the experimental data.…”
Section: The Isotope Abundance Analysis Ms/ms Methodsmentioning
confidence: 99%
“…We recently developed a new isotope abundance analysis (IAA) method and software 2,3 which we named Tal-Aviv. Various forms of IAA have also been described by several other authors [4][5][6][7][8][9][10][11][12][13] The Tal-Aviv IAA software is used to derive elemental formula information from experimental mass spectral data of molecular ion isotopomeric abundances. The software can also be used to automatically confirm or reject the search results coming from an EI spectral library search application such as NIST (National Institute of Standards and Technology), 14 thereby significantly improving the confidence level in sample identifications.…”
mentioning
confidence: 99%
“…Chemicals may also be absorbed from the outside by using haircare products, for example, leading to the contamination of the hair as a sample matrix. Since hair is a non-viable biological matrix in which biological processes no longer take place, parameters can be detected for many months or even years, depending on hair length (Bogdanov et al 2006). Hair has already been used in HBM for the determination of brominated flame retardants (Liang et al 2016 ;Poon et al 2014 ;Zhao et al 2020), pesticides (Park et al 2021 ;Polledri et al 2021), per-and polyfluoroalkyl substances (Piva et al 2021 ;Ruan et al 2019), and polycyclic aromatic hydrocarbons (Schummer et al 2009 ;Toriba et al 2003), to cite a few examples.…”
Section: Biological Matricesmentioning
confidence: 99%
“…Collecting samples of hair is safe for human health, and preliminary studies of hair can involve large groups of subjects. However, there is one important peculiarity of hair-its ability to absorb endogenic substances from a human organism and preserve them in a practically invariable state for an extended length of time (ranging from several months to several years) [10,11].…”
Section: Introductionmentioning
confidence: 99%